Component Objects

Remote Control Bus:

The Remote Control Bus provides connection for

Volume 8

,

Select 8

,

Volume/Select 8

,

Voltage Control Box

, and

Logic Box

external control devices (see

Remote

Control Bus

for more information).

Power Entrance:

The Power Entrance provides connection for the appropriate power cord

(included with unit). An internal universal switching power supply accepts 100~240VAC @
50/60Hz, with a maximum power consumption of 65 Watts.

Front Panel Indicators:

The Front Panel Indicators (I/O, Com, & Status) are 2-color LEDs.

The following table lists their behavior:

All LEDs green

Normal operating state. Configuration was successful (if applicable).
Device is in a stable state awaiting commands.

I/O LED red

Internal audio hardware error.

Com LED red

Serial Port error.

Ethernet error.

CAN Bus error.

No IP address defined (cleared by setting IP address).

Status LED red

Configuration error.

Last configuration unsuccessful (cleared by 'reset/initializing' the
device). Operating systems resource error.

File system error.

DSP error.

All LEDs blinking

Operating system is not executing. Device must be power cycled.