blocks should typically receive 'far-end' (

Codec In

) and ‘program’ signals only (not microphones),

and be connected as close as possible to the output, so as to reflect any level adjustments and
signal processing applied for local sound reinforcement of those same signals. This approach
provides the most accurate reference. AEC Ref blocks should never be connected to paths
containing signal from corresponding AEC Inputs.

Each NEXIA VC comes pre-configured from the factory with a

default system design

. If you wish

to load your own custom designed configuration you will need to

reset/initialize

the unit(s) first.

VC - Pre-AEC 8 Channel

NEXIA VC hardware is represented in the Layout with as many as seven
separate blocks. Between these blocks can be placed virtually any of the
other available NEXIA mixing, routing, and processing blocks (component
objects). Like other component objects, NEXIA VC blocks can be placed
into the Layout either from the

Processing Library

or from the

Object

Toolbar

. To access VC – Pre-AEC 8 Channel settings, double-click over

the corresponding block in the Layout. This opens a Control Dialog Box
which provides all available settings.

When placing a Nexia VC into the Layout, the VC – Pre-
AEC 8 Channel

block is optional. It provides the same set

of input signals as the

VC - AEC Input 8 Channel

block.

However, the signals are derived from the input preamp
directly, and are not affected by AEC or Noise Reduction
processing. Pre-AEC input signals can be used to feed
‘local’ outputs, while the AEC input signals are used to feed
the ‘far end’ (

Codec Out

).

Device IO

indicates which hardware input is associated

with that software channel. Peak In should flash only
occasionally (6dB headroom), as determined by

AEC Input

Gain In settings. Mute In turns the input signal on/off. Level
(dB) In

adjusts the relative input volume. Invert In reverses

the polarity of the input signal.

Right-clicking over certain settings will provide a menu of
additional options.

Each NEXIA VC comes pre-configured from the factory with
a

default system design

. If you wish to load your own

custom designed configuration you will need to

reset/initialize

the unit(s) first.