Standard mixers, Matrix mixers, Room combiners – Biamp LTR User Manual
Page 122: Room, Combiners, See stand, See mat, See room co
Nexia Manual LTR
Standard Mixers
Mute In
turns the input signal on/off. Level In
adjusts the relative input volume. Ch / Bus assigns
inputs to specific outputs. Mute Out turns the output
signal on/off. Level Out adjusts the relative output
volume.
Right-clicking over certain settings will provide a
menu of additional options. Unlike other
components, Mixers allow labeling of inputs/outputs
within their dialog boxes. See Channel Identifier
under
.
Matrix Mixers
Mute In
turns the input signal
on/off. Level In adjusts the
relative input volume. Ch / Bus
assigns inputs to specific
outputs, and right-clicking
allows level adjustment. Mute
Out
turns the output signal
on/off. Level Out adjusts the
relative output volume.
Matrix Mixers w/Delay are also
available. Mix Table assigns
Ch / Bus to affect either level or
delay settings.
Right-clicking over certain settings will provide a menu of additional options. Unlike other
components, Mixers allow labeling of inputs/outputs within their dialog boxes. See Channel
Identifier
under
.
Room Combiners
Room Combiners are provided to enhance the capabilities of Auto Mixers in room combining
and zone routing applications. Room Combiners automatically determine proper routing of audio
signals & control data for the Auto Mixers. Control data represents NOM (number of open mics)
and ATS (adaptive threshold sensing) information. Room Combiners are available only from the
(not from the Processing Library).
108