Vcb calibration, Ss the – Biamp LTR User Manual

Page 30

background image

Nexia Manual LTR

VCB Calibration

Once a VCB (

Voltage Control Box

) block has been assigned in a Nexia configuration, and the

VCB device (with potentiometers attached) is connected to the Nexia

Remote Control Bus

, the

potentiometers can be calibrated for accurate tracking of levels (see

Device Maintenance

).

The first screen encountered in this process allows for
the selection of the potentiometer Channel to be
calibrated. Channel numbers correspond to the Analog
potentiometer connections on the VCB itself. Only one
potentiometer Channel can be calibrated at a time, and
only Channels with potentiometers actually connected
will be available.

Once the Channel
has been selected,
this screen will
prompt the user to
adjust the
corresponding
potentiometer (on
the selected
Channel) to its
maximum (highest)
physical setting,
then select "Next".

Once the maximum
potentiometer
setting has been
recorded, this
screen will prompt
the user to adjust
the same
potentiometer to its
minimum (lowest)
physical setting,
then select "Next".

16