Audio wiring diagrams – Biamp LTR User Manual
Page 16
Nexia Manual LTR
When the user first places a Source Selection
block into an Nexia layout, this prompts an
initialization window.
Source Channel Count specifies the number of input
channels (2 to 16) and generally corresponds to the
number of sources from which the user can choose. If the
Source Channel Count is set to Custom, the Chan Count
parameter is used to specify the exact number of
channels desired.
If selected, Enable Logic provides a logic input and output
connection point for each channel.
Source Selection is represented in the layout
as a block with a number of audio input
connections (specified by the Source Channel
Count parameter), one audio output
connection, and optionally, a logic input and
output connection point for each channel. If
logic is enabled, a low-to-high logic transition
(i.e., a rising edge) presented to a logic input
connection will cause the Source Selection
block to switch to the corresponding audio
input channel, and the corresponding logic out
connection will be at a logic high. All other
logic outputs will be low.
Double clicking on a Source Selection block produces a
control window.
Level (dB) adjusts the level (-100 to 12 dB) of the source
connected to that channel’s input.
Source Selection buttons are used to select the input
source that is routed to the audio output connector of the
Source Selection block. If the user right clicks a source
selection button, this produces a dialog box that allows
customization of the text that is displayed on that button.
This dialog box can be minimized to create user control
surfaces (see Customizing Component Objects).
Audio Wiring Diagrams