Control dialogs, Leveler, Comp/limiter – Biamp LTR User Manual
Page 133: See l, See comp/li
Component Objects
see Ambient Noise Compensator Control Dialog
Right-clicking over the object provides a pop-up menu of options. Control Dialog Boxes for some
Dynamics components can be minimized to create user control surfaces (see
).
Control Dialogs
Leveler
Levelers are automatic gain controls, which affect long-term
average levels. Response Time determines how quickly the
Leveler reacts to input level changes. Threshold determines what
input level will trigger gain reduction. To maintain a consistent level,
set Threshold to lowest desired level. A meter & numeric display
indicate the amount of gain reduction. Identifier provides a custom
label, when dialog box is minimized (see below). Bypass disables
the Leveler without changing settings.
Right-clicking over certain settings will provide a menu of additional
options. Control Dialog Boxes for Levelers can be minimized to
create user control surfaces (see
Comp/Limiter
Comp/Limiters affect short-term signal dynamics
(peaks). Attack determines how quickly the
Comp/Limiter reacts to input level changes.
Compression Ratio
determines the intensity of gain
reduction (input level increase vs. output level
increase). Release Time determines how quickly gain
reduction is released, once input signal falls below
Threshold. Threshold determines what input level will
trigger gain reduction. A meter & numeric display
indicate the amount of gain reduction. Bypass
disables the Comp/Limiter without changing settings.
Identifier
provides a custom label, when dialog box is
minimized (see below).
Right-clicking over certain settings will provide a
menu of additional options. Control Dialog Boxes for
Comp/Limiters can be minimized to create user
control surfaces (see
).