System connect considerations – Biamp LTR User Manual
Page 171
System Design
System Connect Considerations
The System Connect screen provides a System List (configured devices only) and a Device List
(all configured and non-configured devices). When a selection is made in the System List,
Connect To System
will establish communication with, and retrieve the configuration from, the
device(s) in that system. Send System Config will attempt to send an open file of a properly
compiled system configuration to the device(s) specified in the
. If the specified
device(s) have an existing system configuration, they may need to be
before a
new configuration can be sent successfully. Reset/Initialize, as well as other device related
settings, can be accessed by selecting Device Maintenance.
Nexia software now employs the concept of "multi-client sessions". This is simply the capability
for multiple users to be connected to the same system simultaneously. Multi-client sessions also
allow a single user (PC) to be connected to multiple systems. In addition, a single user (PC) can
even have multiple connections to the same system. These multi-client sessions can include
connections from both Nexia software and daVinci control software.
Multi-client sessions include two 'privilege levels'. A High Privilege Session (designated HPS in
the
) is assigned to the first user connected to the system. HPS allows all system
maintenance normally associated with that specific user (see
). Any additional
connections to that system will be Low Privilege Sessions (designated LPS in the
),
which allow system control only, regardless of user. When an HPS user disconnects, privilege
levels do not update (connected users remain LPS), and the next new user connection is
assigned as HPS.
157