Equalizer blocks – Biamp LTR User Manual
Page 195
System Control
Example: Set Device 1 Room Combiner Wall State at Instance 4 Wall 2 to up (close/separate).
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
SET 1
RMCMBWALL
4 2 None
1
Result: SET 1 RMCMBWALL 4 2 1
Mix-Minus Combiner
Attribute
Commands
Index
Value Range
Group State
MCMBGROUP
SET, GET
1
0 ~ 32
Note
: Index1 is the input being addressed. Value is the group; this is represented by a letter in Nexia software, but
addressed as a number in ATP commands. (Example: ungroup=0, A=1, B=2, C=3….)
Equalizer Blocks
* Can contain a decimal number.
Note:
Index1 represents the filter to be controlled. Graphic EQ filters are numbered from left to
right, and the selected band is displayed in the upper left hand corner of the Graphic EQ dialog
screen in Nexia software. Use this number as Index1 for Graphic EQ strings.
Example: Set Device 2 Graphic EQ Bypass All Bands at Instance 9 to bypass.
Result: SET 2 GEQBYPALL 9 1
181