Standard Mixer

Attribute

Commands

Index

Value Range

Input Level

SMLVLIN

SET, SETL, GET, GETL, INC,
DEC

1

-100 ~ 12 *

Output Level

SMLVLOUT

SET, SETL, GET, GETL, INC,
DEC

2

-100 ~ 12 *

Input Mute

SMMUTEIN

SET, GET

1

0 = unmuted

1 = muted

Output Mute

SMOUTMUTE

SET, GET

2

0 = unmuted

1 = muted

Crosspoint Mute

SMMUTEXP

SET, GET

1 & 2 1 = unmuted

0 = muted

* Can contain a decimal number.

Note:

For attributes with 2 Index fields, Index1 is the input/row, and Index2 is the output/column.

Room Combiner

Attribute

Commands

Index

Value Range

Wall State

RMCMBGROUP

SET, GET

1

0 = down

1 = up

Output Level

RMCMBLVL

SET, SETL, GET, GETL, INC,
DEC

2

-100 ~ 12 *

Output Mute

RMCMBMUTE

SET, GET

2

0 = unmuted

1 = muted

Group State

RMCMBGROUP

SET, GET

1

0 ~ 16

* Can contain a decimal number.

+ Note: The behavior of RMCMBGROUP is the same as that of the "Set Selected Group" commands in the right-click-
context menus of the Room Combiner dialog screen in Nexia Software: the specified room is either separate (group 0) or
combined with other rooms of the selected group (1~16). All other rooms maintain their previous group assignments.
Index1 represents the room being addressed. As rooms are combined, room levels become ganged, so only one output
level needs to be addressed.

Note:

For Wall State, Index1 indicates the wall to be affected and Value indicates the actual wall

state (down=open=combined; up=closed=separated).