Attribute
The Attribute defines the portion of the DSP block to be controlled (fader level, crosspoint mute
etc). The following tables show whether each NTP Attribute supports SET/SETL, GET/GETL,
INC, and DEC
, as well as the
range that the Attribute will accept.
Index1/Index2 determines whether
or BOTH are needed for a NTP String to be
complete.
NTP Strings can address: (click on the links to view the tables in each topic)
Input/Output Blocks
The following
table of Attributes is valid for all Nexia input blocks
except
Nexia PM Stereo Line
Inputs, Nexia TC & Nexia VC AEC Inputs, and Nexia TC & Nexia VC Pre-AEC Inputs.
Analog Inputs
Attribute
Commands
Index
Value Range
Input Gain
INPGAIN
SET, SETL, GET, GETL,
INC, DEC
1
0, 6, 12, 18, 24, 30, 36,
42, 48, 54, 60, 66
Input Level
INPLVL
SET, SETL, GET, GETL,
INC, DEC
1
-100 ~ 12 *
Phantom Power
PHPWR
SET, GET
1
0 = off
1 = on
Input Mute
INPMUTE
SET, GET
1
0 = unmuted
1 = muted
172