beautypg.com

Attribute, Input/output blocks, Sectio – Biamp LTR User Manual

Page 186

background image

Nexia Manual LTR

Attribute

The Attribute defines the portion of the DSP block to be controlled (fader level, crosspoint mute
etc). The following tables show whether each NTP Attribute supports SET/SETL, GET/GETL,
INC, and DEC

Commands

, as well as the

Value

range that the Attribute will accept.

Index1/Index2 determines whether

Index1

,

Index2

or BOTH are needed for a NTP String to be

complete.

NTP Strings can address: (click on the links to view the tables in each topic)

Input/Output Blocks

Mixer Blocks

Equalizer Blocks

Filter Blocks

Crossover Blocks

Dynamics Blocks

Router Blocks

Delay Blocks

Control Blocks

Meter Blocks

Generator Blocks

Input/Output Blocks

The following

table of Attributes is valid for all Nexia input blocks

except

Nexia PM Stereo Line

Inputs, Nexia TC & Nexia VC AEC Inputs, and Nexia TC & Nexia VC Pre-AEC Inputs.

Analog Inputs

Attribute

Commands

Index

Value Range

Input Gain

INPGAIN

SET, SETL, GET, GETL,
INC, DEC

1

0, 6, 12, 18, 24, 30, 36,
42, 48, 54, 60, 66

Input Level

INPLVL

SET, SETL, GET, GETL,
INC, DEC

1

-100 ~ 12 *

Phantom Power

PHPWR

SET, GET

1

0 = off

1 = on

Input Mute

INPMUTE

SET, GET

1

0 = unmuted

1 = muted

172

This manual is related to the following products: