Meter blocks, Generator blocks, Instance id – Biamp LTR User Manual

Page 203: Number, Assignment, Instanceid, Instance id tags

background image

System Control

Note

: Instead of SET, SETL, GET, GETL, INC, or DEC; the Preset attribute uses RECALL as the

command. Preset numbers begin at 1001. Regardless of preset name, the first preset defined is
1001, the second is 1002, and so forth. However, the numbers of any deleted Presets will not be
available. Since Presets apply to entire systems, the Device Number will always be 0 for Preset
strings.

Example: Recall Device 0 Preset number 1001.

Result: RECALL 0 PRESET 1001 (use RECALL instead of SET/GET commands)

Meter Blocks

* Can contain a decimal number.

Note:

Meters only use GET and GETL commands, which do not include a Value. Instead, Nexia

will respond to these GET/GETL commands with the requested value (current level).

Example: Get Device 1 RMS Meter Level at Instance 48 Meter 1.

Result: GET 1 RMSMTRLVL 48 1 (use GET/GETL commands only)

Generator Blocks

No Attributes are specified at this time

Instance ID

189