Biamp LTR User Manual
Page 191
System Control
Note:
GET 1 TICIDUSER 23 will return: "" "" "" if there is no caller ID information available.
The first set of quotes contains the date and time in the format MMDDHHmm. The second set
of quotes represents the incoming phone number in the format 5036417287. The third set of
quotes contains the name of the caller. If there are quotes contained within the name, there
will be a backslash preceding the quotes within the name, i.e. "David \"Dawg\" Grisman".
Example: Set Device 1 TC Speed Dial Entry at Instance 23 Speed Dial 16 to 1-800-826-1457.
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
FLASH 1
TILINE
23 None None None
Result: FLASH 1 TILINE 23
Example: Set Device 1 TC Speed Dial Entry at Instance 23 Speed Dial 16 to 1-800-826-1457.
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
SET 1 TISDENTRY 23 16 None
18008261457
Result: SET 1 TISDENTRY 23 16 18008261457
Example: Dial Device 1 TC Phone Number To Dial at Instance 23 of 1-800-826-1457.
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
DIAL 1
TIPHONENUM
23 None
None
18008261457
Result: DIAL 1 TIPHONENUM 23 18008261457
commands)
TC Receive
Attribute
Commands
Index
Value Range
Receive Level
TIRXLVL
SET, SETL, GET, GETL,
INC, DEC
None
-100 ~ 12 *
Receive Mute
TIRXMUTE
SET, GET
None
0 = unmuted
1 = muted
Number of
TIAUTOANSWER
SET, GET
None
0 = off
177