beautypg.com

HP Anab EQ5 User Manual

Page 67

background image

TECO

–Westinghouse Motor Company Function Explanation 61

Related functions

E01 to E09

(Set values:14)

Related functions

U01
U60

Related functions

E01E09

(Set value: 14)


This function switches the frequency setting method

set in function codes F01 and C30 by an external
digital input signal.
This

is

the

reverse-logic

of

setting

value

"11"(Frequency

setting

2/Frequency

setting

1

[Hz2/Hz1]).

Set value input signal

Frequency setting method selected

35

off

C30 FREQ CMD2

on

F01 FREQ CMD1

Note: It can not be used with set value "11"
simultaneously. When the set value "11" and "35" are
selected, "Er6" is displayed.



Digital

input

Setting at factory shipment

Set

value

Description

Terminal X1

0

Multistep frequency selection [SS1]

Terminal X2

1

Multistep frequency selection [SS2]

Terminal X3

2

Multistep frequency selection [SS4]

Terminal X4

3

Multistep frequency selection [SS8]

Terminal X5

4

Acceleration and deceleration selection [RT1]

Terminal X6

5

Acceleration and deceleration selection [RT2]

Terminal X7

6

Self-hold selection [HLD]

Terminal X8

7

Coast-to-stop command [BX]

Terminal X9

8

Alarm reset [RST]












Acceleration time 1 (F07) and deceleration time 1 (F08)

as well as three other types of acceleration and
deceleration time can be selected.

The operation and setting ranges are the same as those

of acceleration time 1 and deceleration time 1. See
explanations for F07 and F08.

For switching acceleration and deceleration times, select

any two terminals from terminal X1 (function selection) in
E01 to terminal X9 (function selection) in E09 as
switching signal input terminals. Set "4" (acceleration
and deceleration time 1) and "5" (acceleration and
deceleration time 2) to the selected terminals and input a
signal to each terminal to switch acceleration and
deceleration times. Switching is possible during
acceleration, deceleration, or constant-speed operation.















Example: When 4 and 5 are set to terminals X2 and X3:

ON

Time

ON

ON

FWD

(REV)

X2

X3

P24

Operation

Output
frequency

Maximum
frequency

Accel
time
1

Decel
time
1

Accel
time
2

Decel
time
2

Accel
time
3

Decel
time
3

Accel
time
4

Decel
time
4



This function is used to switch the torque limit level set

in F40 and F41 by an external control signal. Input an
external signal by selecting any of the control input
terminals (X1 to X9) as torque limit 2/torque limit 1
(value 14) in E01 to E09.

The motor tuning (P04 / A13) should be set to "2" for

this function is valid.

Maximum compensation frequency during braking torque limit

is set by U01.



The operation mode is set by U60 when the setting

value is "0%: Regeneration avoidance at deceleration".
The detail is referred to the U01, U60.



E 1 6

D R V

T R Q

2

E 1 7

B R K

T R Q

2

E16

Torque limiter 2 (driving)

Torque limiter 2 (braking)

E17

Settings when shipped from the factory

E10

Acceleration time 2

E11

Deceleration time 2

E12

Acceleration time 3

E13

Deceleration time 3

E14

Acceleration time 4

E15

Deceleration time 4

E 1 0

A C C

T I M E 2

E 1 1

D E C

T I M E 2

E 1 2

A C C

T I M E 3

E 1 3

D E C

T I M E 3

E 1 4

A C C

T I M E 4

E 1 5

D E C

T I M E 4

Frequency setting 1 / Frequency setting 2 [Hz1/Hz2]

This manual is related to the following products: