beautypg.com

Eq5 ac drive operations manual – HP Anab EQ5 User Manual

Page 23

background image


EQ5 AC Drive Operations Manual

_____________________________________________________________________

TECO – Westinghouse Motor Company Control Terminal Designations & Wiring 17

2-3-3 Connecting the Control Terminals

Table 2-3-3 lists the functions of the control circuit terminals. The connections to the control
terminals will be in accordance with its function setting.

Table 2-3-3 Control Terminal Functions

Classification

Terminal

Symbol

Terminal Name

Function

Analog input

13

Potentiometer
power supply

Supplies +10V DC to an externally connected frequency
control potentiometer (1 to 5k

Ω).

12 Voltage

input

1

1- Sets the output frequency in accordance with an analog

input voltage applied from an external circuit.

- 0 to +10V DC / 0 to 100%
- Reversible operation using positive and negative

signals: 0 to +/-10V DC / 0 to +/-100%

- Reverse operation: +10 to 0V DC / 0 to 100%

2- Feedback signal for PID control.
3- Output torque control.
* Terminal Input resistance: 22k

V2 Voltage

input

2

Sets the output frequency in accordance with an analog
input voltage applied from an external circuit.

- 0 to +10V DC / 0 to 100%
- Reverse operation:+10 to 0V DC / 0 to 100%

* Terminals "V2" and "C1" cannot be used at the same time.
* Terminal Input resistance: 22k

C1 Current

input

1- Sets the output frequency in accordance with an analog

input current applied from an external circuit.

- 4 to 20mA DC / 0 to 100%
- Reverse operation: 20 to 4mA DC / 0 to 100%

2- Feedback signal for PID control.
3- PTC thermistor input.

13

C1

V2

11

11k

11k

1k

ON

OFF

PTC

+

_

250


* Terminals "V2" and "C1" cannot be used at the same time.
* Terminal Input resistance: 250

* PTC switch is off when function not used.

11

Analog input
common

Common terminal for analog input and output signals

This manual is related to the following products: