EQ5 AC Drive Operations Manual

_________________________________________________________________________

TECO – Westinghouse Motor Company Standard Specifications Notes con’t 10

5

EQ5 CT (Constant Torque) – 460V Series

Type

Nema 1

Open Chassis

Applied Motor

Nominal (HP)

0.5 1 2 3 5 5 7.5 10 15

20

25

30

30 40

50

60

75 100 125 150 200

250

300

350

350 400 450 500 600

Type
EQ5-4XXX-XX

0P5

-N1

001-

-N1

002-

-N1

003
-N1

005
-N1

005
-N1

010
-N1

015
-N1

020
-N1

025
-N1

030
-N1

032
-N1

040

-C

050

-C

060

-C

075

-C

100

-C

125

-C

150

-C

200

-C

250

-C

300

-C

350

-C

400

-C

450

-C

500

-C

600

-C

700

-C

800

-C

Rated capacity
[kVA] (*1)

1.2 2.0 2.9 4.4 7.2 7.2 10 14 19

24

31

36

36 48

60

73

89 120 140 167 202 242 300 331 331 414 466 518 590

Rated output
current [A] (*2)

1.5 2.5 3.7 5.5 9 9 13 18 24

30

39

45

45 60

75

91 112 150 176 210 253 304 377 415 415 520 585 650 740

Overload
capability

150% of rated output current for 1 min.
200% of rated output current for 0.5 s

150% of rated output current for 1 min.
180% of rated output current for 0.5 s

Starting torque

200% or more (under torque vector control)

180% or more (under torque vector control)

Outpu

t

rating

s

Rated output
Voltage [V] (*3)

3-phase, 380V, 400V, 415V(440V)/50Hz, 380V, 400V, 440V, 460V/60Hz

Rated output
frequency [Hz]

50,60Hz

Inpu

t ra

ting

s

Phases, voltage,
frequency

3-phase,380 to 480V,50/60Hz

3-phase, 380 to 440V/50Hz (*5)
3-phase, 380 to 480V/60Hz

Voltage/frequency
variations

Voltage: +10% to -15% (Imbalance rate between phases: 2% or less (*5) , Frequency: +5% to -5%

Momentary
voltage dip
capability (*6)

Operation will continue with 310V or more. If voltage drops below 310V, operation will continue for up to 15 ms.
If "Continuous operation" is selected, the output frequency will be lowered to withstand the load until normal voltage is resumed.

Required power
supply capacity
[kVA] (*7)

0.7 1.2 2.2 3.1 5.0 5.0 7.2 9.7 15

20

24

29

29

38

47

57

70

93 111 136 161 196 244 267 267 341 383 433 488

EQ5 VT (Variable Torque) – 460V Series

Type

Nema 1

Open Chassis

Applied Motor

Nominal (HP)

0.5 1 2 3 5 7.5 10 15 20

25

30

30

40 50

60

75 100 125 150 200 250

300

350

400

450 500 600 700 800

Type
EQ5-4XXX-XX

0P5

-N1

001-

-N1

002-

-N1

003
-N1

005
-N1

005
-N1

010
-N1

015
-N1

020
-N1

025
-N1

030
-N1

032
-N1

040

-C

050

-C

060

-C

075

-C

100

-C

125

-C

150

-C

200

-C

250

-C

300

-C

350

-C

400

-C

450

-C

500

-C

600

-C

700

-C

800

-C

Rated capacity
[kVA] (*1)

1.2 2.0 2.9 4.4 7.2 10 13 18 24

29

35

36

48 60

73

89 120 140 167 202 242 300 331 386 414 518 590 669 765

Rated output
current [A] (*2)

1.5 2.5 3.7 5.5 9 12.5

16.5 23 30

37

44

45

60 75

91 112 150 176 210 253 304 377 415 485 520 650 740 840 960

Overload
capability

110% of rated output current for 1 min.

Starting torque

50% or more

Outpu

t

rating

s

Rated output
voltage [V] (*3)

3-phase, 380V, 400V, 415V(440V)/50Hz, 380V, 400V, 440V, 460V/60Hz

Rated output
frequency [Hz]

50,60Hz

Inpu

t ra

ting

s

Phases, voltage,
frequency

3-phase,380 to 480V,50/60Hz

3-phase, 380 to 440V/50Hz (*4)
3-phase, 380 to 480V/60Hz

Voltage/frequency
variations

Voltage: +10% to -15% (Imbalance rate between phases: 2% or less (*5) , Frequency: +5% to -5%

Momentary
voltage dip
capability (*6)

Operation will continue with 310V or more. If voltage drops below 310V, operation will continue for up to 15 ms.
If "Continuous operation" is selected, the output frequency will be lowered to withstand the load until normal voltage is resumed.

Required power
Supply capacity
[kVA] (*7)

0.7 1.2 2.2 3.1 5.0 7.2 9.7 15 20

24

29

29

38

47

57

70

93 111 136 161 196 244 267 341 383 433 488 549 610


(*1) Indicated capacities are at the rated output voltage 230V for the 230V series and 460V for the 460V series. The rated capacity will be lowered if the

supply voltage is lower.

(*2) In the case of a low impedance load, such as a high-frequency motor, the current may drop below the rated value.
(*3) The output voltage cannot exceed the input supply voltage.