TECO

–Westinghouse Motor Company Function Explanation 59

This function switches the torque limit value set in
function codes F40 and F41, and E16 and E17 by an
external digital input signal.

Set value input signal


Torque limit
value selected

14

off

F40 DRV TRQ1
F41 BRK TRQ1

Setting range
DRV 20 to 200% ,999
BRK 0, 20 to 200% ,999

on

E16 DRV TRQ2
E17 BRK TRQ2


Motor operation can be switched from 50Hz commercial
power operation to inverter operation without stopping the
motor by switching the external digital input signal.

Set value
input signal

Function

15

off

on

Inverter operation to line operation (50Hz)

on

off

Line operation to inverter operation (50Hz)


Motor operation can be switched from 60Hz commercial
power operation to inverter operation without stopping the
motor by switching the external digital input signal.

Set value
input signal

Function

16

off

on

Inverter operation to line operation (60Hz)

on

off

Line operation to inverter operation (60Hz)

When the digital input signal goes off, 50 or 60 Hz is

output according to the set value input signal after the
restart waiting time following a momentary power failure
(function code H13). The motor is then directed to
inverter operation.

WARNING

- After the LU(Low Voltage) trip is occurred and reset,
the inverter will automatically restart because the
operation command is kept by internal sequence.
Accidents may result.

When an operation command is input (on), the output
frequency can be increased or decreased by an external
digital input signal.
The change ranges from 0 to maximum frequency.
Operation in the opposite direction of the operation
command is not allowed.














Combination of set
value input signals

Function selected

(when operation command is on)

18

17

off

off

Holds the output frequency.

off

on

Increases

the

output

frequency

according to the acceleration time.

on

off

Decreases the output frequency
according to the deceleration time.

on

on

Holds the output frequency.

There are the two types of UP/DOWN operations as
shown below. Set the desired type by setting the
frequency (F01 or C30).

The data "8: UP/DOWN 1" is valid only when the Motor

2 is selected.

Frequency

setting

(F01 or C30)

Initial value

at power

input on

Operation command reentry

during deceleration

8

(UP/DOWN1)

0Hz

Operates at the frequency at reentry.

Frequency


FWD ON
(REV) OFF

9

(UP/DOWN2)

Previous

frequency

Returns to the frequency before
deceleration

Frequency

FWD ON
(REV) OFF



This function allows the data to be changed only when an
external signal is being input, thereby making it difficult to
change the data.

19

Function selected

off

Inhibit data changes.

on

Allow data changes.

Note:
If a terminal is set to value 19, the data becomes unable
to be changed. To change the data, turn on the terminal
and change the terminal setting to another number.

The PID control can be disabled by an external digital
input signal.

Set value
input signal


Function selected

20

off

Enable PID control.

on

Disable PID control

(frequency setting from keypad panel).

UP command [UP]/DOWN command [DOWN]

Write enable for KEYPAD [WE-KP]

PID control cancel [Hz/PID]

Related function

H20H25

Switching operation between line and inverter (50Hz) [SW50]

Switching operation between line and inverter (60Hz) [SW60]

Torque limit 2/torque limit 1 [TL2/TL1]

Related function

F40F41

E16E17

Write enable for KEYPAD [WE-KP]

Related function

E01E09

(set value: 11, 35)

Related function

F01, C30

This manual is related to the following products: