Eq5 ac drive operations manual, E parameters, C parameters – HP Anab EQ5 User Manual
Page 49: Cont
EQ5 AC Drive Operations Manual
_______________________________________________________________________
TECO – Westinghouse Motor Company Parameter List E01 – E47 & C01 – C19 43
E Parameters
Para.
No.
NAME
LCD Display
Setting range
Unit
Min.
Unit
Factory setting
Change
During
Oper.
User
Set value
Remark
30HP/CT
40HP/VT
40HP/CT
50HP/VT
E01 X1 terminal function
E01
X1 FUNC
0 to 35
-
-
0 N
E02 X2 terminal function
E02
X2 FUNC
1 N
E03 X3 terminal function
E03
X3 FUNC
2 N
E04 X4 terminal function
E04
X4 FUNC
3 N
E05 X5 terminal function
E05
X5 FUNC
4 N
E06 X6 terminal function
E06
X6 FUNC
5 N
E07 X7 terminal function
E07
X7 FUNC
6 N
E08 X8 terminal function
E08
X8 FUNC
7 N
E09 X9 terminal function
E09
X9 FUNC
8 N
E10 Acceleration time 2
E10
ACC TIME2
0.01 to 3600s
s 0.01
6.00 20.00 Y
E11 Deceleration time 2
E11
DEC TIME2
6.00 20.00 Y
E12 Acceleration time 3
E12
ACC TIME3
6.00 20.00 Y
E13 Deceleration time 3
E13
DEC TIME3
6.00 20.00 Y
E14 Acceleration time 4
E14
ACC TIME4
6.00 20.00 Y
E15 Deceleration time 4
E15
DEC TIME4
6.00 20.00 Y
E16 Torque limiter 2 (Driving)
E16
DRV TRQ 2
20 to 150%, 999
%
1
999
Y
E17 (Braking)
E17
BRK TRQ 2
0%, 20 to 150%, 999
%
1
999
Y
E20 Y1 terminal function
E20
Y1 FUNC
0 to 37
-
-
0 N
E21 Y2 terminal function
E21
Y2 FUNC
1
N
E22 Y3 terminal function
E22
Y3 FUNC
2
N
E23 Y4 terminal function
E23
Y4 FUNC
7
N
E24 Y5A, Y5C terminal func.
E24
Y5 FUNC
10
N
E25 Y5 RY operation mode
E25
Y5RY MODE
0,1
-
1
0
N
E30 FAR function (Hysteresis)
E30
FAR HYSTR
0.0 to 10.0Hz
Hz
0.1
2.5
Y
E31 FDT function (Level)
E31
FDT1 LEVEL
0 to 120Hz
Hz
1
60
Y
E32 Signal (Hysteresis)
E32
FDT1 HYSTR
0.0 to 30.0Hz
Hz
0.1
1.0
Y
E33 OL1 function(Mode select)
E33
OL1 WARNING
0: Thermal calculation
-
-
0 Y
1: Output current
E34 Signal (Level)
E34
OL1 LEVEL
5 to 200%
A
0.01
Motor rated current
Y
E35 (Timer)
E35
OL1 TIMER
0.0 to 60.0s
s
0.1
10.0
E36 FDT2 function (Level)
E36
FDT2 LEVEL
0 to120Hz
Hz
1
60
Y
E37 OL2 function (Level)
E37
OL2 LEVEL
5 to 200%
A
0.01
Motor rated current
Y
E40 Display coefficient A
E40
COEF A
-999.00 to 999.00
-
0.01
0.01
Y
E41 Display coefficient B
E41
COEF B
-999.00 to 999.00
-
0.01
0.00
Y
E42 LED Display filter
E42
DISPLAY FL
0.0 to 5.0s
s
0.1
0.5
Y
E43 LED Monitor (Function)
E43
LED MNTR
0 to 12
-
-
0
Y
E44 (Display at STOP mode)
E44
LED MNTR2
0, 1
-
-
0
Y
E45 LCD Monitor (Function)
E45
LCD MNTR
0, 1
- -
0
Y
E46 (Language)
E46
LANGUAGE
0 to 5
-
-
1
Y
E47 (Contrast)
E47
CONTRAST
0 (soft) to 10 (hard)
-
-
5
Y
C Parameters
Para.
No.
NAME
LCD Display
Setting range
Unit
Min.
Unit
Factory setting
Change
During
Oper.
User
Set value
Remark
30HP/CT
40HP/VT
40HP/CT
50HP/VT
C01
Jump frequency
(Jump freq. 1)
C01
JUMP Hz 1
0 to 120Hz
Hz
1
0
Y
C02
(Jump freq. 2)
C02
JUMP Hz 2
0
C03
(Jump freq. 3)
C03
JUMP Hz 3
0
C04
(Hysteresis)
C04
JUMP HYSTR
0 to 30Hz
Hz
1
3
C05
Multistep frequency
setting
(Freq. 1)
C05
MULTI Hz-1
0.00 to 120.00Hz
Hz
0.01
0.00
C06
(Freq. 2)
C06
MULTI Hz-2
0.00
C07
(Freq. 3)
C07
MULTI Hz-3
0.00
C08
(Freq. 4)
C08
MULTI Hz-4
0.00
C09
(Freq. 5)
C09
MULTI Hz-5
0.00
C10
(Freq. 6)
C10
MULTI Hz-6
0.00
C11
(Freq. 7)
C11
MULTI Hz-7
0.00
C12
(Freq. 8)
C12
MULTI Hz-8
0.00
C13
(Freq. 9)
C13
MULTI Hz-9
0.00
C14
(Freq. 10)
C14
MULTI Hz-10
0.00
C15
(Freq. 11)
C15
MULTI Hz-11
0.00
C16
(Freq. 12)
C16
MULTI Hz-12
0.00
C17
(Freq. 13)
C17
MULTI Hz-13
0.00
C18
(Freq. 14)
C18
MULTI Hz-14
0.00
C19
(Freq. 15)
C19
MULTI Hz-15
0.00
Cont.