beautypg.com

Eq5 ac drive operations manual, E parameters, C parameters – HP Anab EQ5 User Manual

Page 49: Cont

background image


EQ5 AC Drive Operations Manual

_______________________________________________________________________

TECO – Westinghouse Motor Company Parameter List E01 – E47 & C01 – C19 43

E Parameters

Para.

No.

NAME

LCD Display

Setting range

Unit

Min.

Unit

Factory setting

Change

During

Oper.

User

Set value

Remark

30HP/CT
40HP/VT

40HP/CT
50HP/VT

E01 X1 terminal function

E01

X1 FUNC

0 to 35

-

-

0 N

E02 X2 terminal function

E02

X2 FUNC

1 N

E03 X3 terminal function

E03

X3 FUNC

2 N

E04 X4 terminal function

E04

X4 FUNC

3 N

E05 X5 terminal function

E05

X5 FUNC

4 N

E06 X6 terminal function

E06

X6 FUNC

5 N

E07 X7 terminal function

E07

X7 FUNC

6 N

E08 X8 terminal function

E08

X8 FUNC

7 N

E09 X9 terminal function

E09

X9 FUNC

8 N

E10 Acceleration time 2

E10

ACC TIME2

0.01 to 3600s

s 0.01

6.00 20.00 Y

E11 Deceleration time 2

E11

DEC TIME2

6.00 20.00 Y

E12 Acceleration time 3

E12

ACC TIME3

6.00 20.00 Y

E13 Deceleration time 3

E13

DEC TIME3

6.00 20.00 Y

E14 Acceleration time 4

E14

ACC TIME4

6.00 20.00 Y

E15 Deceleration time 4

E15

DEC TIME4

6.00 20.00 Y

E16 Torque limiter 2 (Driving)

E16

DRV TRQ 2

20 to 150%, 999

%

1

999

Y

E17 (Braking)

E17

BRK TRQ 2

0%, 20 to 150%, 999

%

1

999

Y

E20 Y1 terminal function

E20

Y1 FUNC

0 to 37

-

-

0 N

E21 Y2 terminal function

E21

Y2 FUNC

1

N

E22 Y3 terminal function

E22

Y3 FUNC

2

N

E23 Y4 terminal function

E23

Y4 FUNC

7

N

E24 Y5A, Y5C terminal func.

E24

Y5 FUNC

10

N

E25 Y5 RY operation mode

E25

Y5RY MODE

0,1

-

1

0

N

E30 FAR function (Hysteresis)

E30

FAR HYSTR

0.0 to 10.0Hz

Hz

0.1

2.5

Y

E31 FDT function (Level)

E31

FDT1 LEVEL

0 to 120Hz

Hz

1

60

Y

E32 Signal (Hysteresis)

E32

FDT1 HYSTR

0.0 to 30.0Hz

Hz

0.1

1.0

Y

E33 OL1 function(Mode select)

E33

OL1 WARNING

0: Thermal calculation

-

-

0 Y


1: Output current

E34 Signal (Level)

E34

OL1 LEVEL

5 to 200%

A

0.01

Motor rated current

Y

E35 (Timer)

E35

OL1 TIMER

0.0 to 60.0s

s

0.1

10.0

E36 FDT2 function (Level)

E36

FDT2 LEVEL

0 to120Hz

Hz

1

60

Y

E37 OL2 function (Level)

E37

OL2 LEVEL

5 to 200%

A

0.01

Motor rated current

Y

E40 Display coefficient A

E40

COEF A

-999.00 to 999.00

-

0.01

0.01

Y

E41 Display coefficient B

E41

COEF B

-999.00 to 999.00

-

0.01

0.00

Y

E42 LED Display filter

E42

DISPLAY FL

0.0 to 5.0s

s

0.1

0.5

Y

E43 LED Monitor (Function)

E43

LED MNTR

0 to 12

-

-

0

Y

E44 (Display at STOP mode)

E44

LED MNTR2

0, 1

-

-

0

Y

E45 LCD Monitor (Function)

E45

LCD MNTR

0, 1

- -

0

Y

E46 (Language)

E46

LANGUAGE

0 to 5

-

-

1

Y

E47 (Contrast)

E47

CONTRAST

0 (soft) to 10 (hard)

-

-

5

Y


C Parameters

Para.

No.

NAME

LCD Display

Setting range

Unit

Min.

Unit

Factory setting

Change

During

Oper.

User

Set value

Remark

30HP/CT
40HP/VT

40HP/CT
50HP/VT

C01

Jump frequency

(Jump freq. 1)

C01

JUMP Hz 1

0 to 120Hz

Hz

1

0

Y

C02

(Jump freq. 2)

C02

JUMP Hz 2

0

C03

(Jump freq. 3)

C03

JUMP Hz 3

0

C04

(Hysteresis)

C04

JUMP HYSTR

0 to 30Hz

Hz

1

3

C05

Multistep frequency

setting



(Freq. 1)

C05

MULTI Hz-1

0.00 to 120.00Hz

Hz

0.01

0.00

C06

(Freq. 2)

C06

MULTI Hz-2

0.00

C07

(Freq. 3)

C07

MULTI Hz-3

0.00

C08

(Freq. 4)

C08

MULTI Hz-4

0.00

C09

(Freq. 5)

C09

MULTI Hz-5

0.00

C10

(Freq. 6)

C10

MULTI Hz-6

0.00

C11

(Freq. 7)

C11

MULTI Hz-7

0.00

C12

(Freq. 8)

C12

MULTI Hz-8

0.00

C13

(Freq. 9)

C13

MULTI Hz-9

0.00

C14

(Freq. 10)

C14

MULTI Hz-10

0.00

C15

(Freq. 11)

C15

MULTI Hz-11

0.00

C16

(Freq. 12)

C16

MULTI Hz-12

0.00

C17

(Freq. 13)

C17

MULTI Hz-13

0.00

C18

(Freq. 14)

C18

MULTI Hz-14

0.00

C19

(Freq. 15)

C19

MULTI Hz-15

0.00

Cont.

This manual is related to the following products: