Eq5 ac drive operations manual, A parameters, U parameters – HP Anab EQ5 User Manual
Page 51
EQ5 AC Drive Operations Manual
_______________________________________________________________________
TECO – Westinghouse Motor Company Parameters A01 – A18 ~ U01 – U89 45
A Parameters
Para.
No.
NAME
LCD Display
Setting range
Unit
Min.
Unit
Factory setting
Change
During
Oper.
User
Set
value
Remark
30HP/CT
40HP/VT
40HP/CT
50HP/VT
A01 Maximum frequency 2
A01
MAX Hz-2
50 to 120Hz
Hz
1
60
N
A02 Base frequency 2
A02
BASE Hz-2
25 to 120Hz
Hz
1
60
N
A03 Rated voltage 2
(at Base frequency 2 )
A03
RATED V-2
0:
V
1
220: (230V class)
N
80 to 240V: (230V class)
380: (460V class)
320 to 480V: (460V class)
A04 Maximum voltage 2
(at Base frequency 2)
A04
MAX V-2
80 to 240V: (230V class)
V
1
220:(230V class)
N
320 to 480V: (460V class)
380:(460V class)
A05 Torque boost2
A05
TRQ BOOST2
0.0, 0.1 to 20.0
-
-
0.1
Y
A06 Electronic thermal overload relay for motor 2
A06
ELCTRN OL2
0, 1, 2
- -
1 Y
A07 (Level)
A07
OL LEVEL2
INV rated current 20%to135%
A
0.01
Motor rated current
Y
A08
(Thermal time constant)
A08
TIME CNST2
0.5 to 75.0 min
min
0.1
5.0
10.0
Y
A09 Torque vector control 2
A09
TRQVECTOR2
0, 1
- -
0
N
A10 Number of motor-2 poles
A10
M2 POLES
2 to 14 poles
poles
2
4
N
A11
Motor 2
(Capacity)
A11
M2-CAP
Up to 30HP:0.01 to 60HP
HP
0.01
Motor capacity
N
40HP and above:0.01to800HP
A12
(Rated current)
A12
M2-Ir
0.00 to 2000A
A
0.01
Motor rated current
N
A13
(Tuning)
A13
M2 TUN1
0, 1, 2
- -
0
N
A14
(On-line Tuning)
A14
M2 TUN2
0, 1
- -
0
N
A15
(No-load current)
A15
M2-Io
0.00 to 2000A
A
0.01
TWMC standard rated value
N
A16
(%R1 setting)
A16
M2-%R1
0.00 to 50.00%
%
0.01
TWMC standard rated value
Y
A17
(%X setting)
A17
M2-%X
0.00 to 50.00%
%
0.01
TWMC standard rated value
Y
A18
(Slip compensation control 2)
A18
SLIP COMP2
0.00 to 15.00Hz
Hz
0.01
0.00
Y
U Parameters
U01 Maximum
compensation
frequency
U01
USER 01
0 to 65535
- 1
75 A
during braking torque limit
U02 1st S-shape level at acceleration
U02
USER 02
1 to 50%
%
1
10
NA
U03 2nd S-shape level at acceleration
U03
USER 03
1 to 50%
%
1
10
NA
U04 1st S-shape level at deceleration
U04
USER 04
1 to 50%
%
1
10
NA
U05 2nd S-shape level at deceleration
U05
USER 05
1 to 50%
%
1
10
NA
U08
Main DC link
capacitor
(Initial value)
U08
USER 08
0 to 65535
-
1 xxxx A
U09
(Measured value)
U09
USER 09
0 to 65535
-
1 0 A
U10 PC board capacitor powered on time
U10
USER 10
0 to 65535h
h
1
0
A
U11 Cooling fan operating time
U11
USER 11
0 to 65535h
h
1
0
A
U13 Magnetize current vibration damping gain
U13
USER 13
0 to 32767
-
1 819
410 A
U15 Slip compensation filter time constant
U15
USER 15
0 to 32767
-
1 556
546 A
U23 Integral gain of continuous operation
U23
USER 23
0 to 65535
-
1
1738 1000 A
at
power
failure
U24 Proportional gain of continuous
U24
USER 24
0 to 65535
-
1
1024 1000 A
operation at power failure
U48 Input phase loss protection
U48
USER 48
0, 1, 2
-
-
-75HP 100HP- NA
0 1
U49 RS-485 protocol selection
U49
USER 49
0, 1
-
-
1 NA
U59
Braking-resistor function select(up to 30HP/CT,
40HP/VT)
U59
USER 59
00 to A8(HEX)
-
1
00 NA
Manufacturer's function(40HP/CT, 50HP/VT or
more)
U60 Regeneration avoidance at deceleration
U60
USER 60
0, 1
-
-
0 NA
U61 Voltage detect offset and gain adjustment
U61
USER 61
--30HP/CT, 40HP/VT:0 (Fixed.)
-
-
0 A
40HP/CT,
50HP/CT--:0, 1, 2
U89 Motor overload memory
U89
USER 89
0.1
-
-
1 A
retention
NOTES