TECO

–Westinghouse Motor Company Function Explanation 69

C 3 0

F R E Q

C M D

2

Pattern operation setting example

Function

Set value

Operation frequency to be set

C21 (operation selection)

1

-

C22 (stage 1)

60.0F2

Multistep frequency 1 (C05)

C23 (stage 2)

100F1

Multistep frequency 2 (C06)

C24 (stage 3)

65.5R4

Multistep frequency 3 (C07)

C25 (stage 4)

55.0R3

Multistep frequency 4 (C08)

C26 (stage 5)

50.0F2

Multistep frequency 5 (C09)

C27 (stage 6)

72.0F4

Multistep frequency 6 (C10)

C28 (stage 7)

35.0F2

Multistep frequency 7 (C11)

The following diagram shows this operation.

Forward
direction

Reverse
direction

Time

ACC2

ACC1

DEC4

ACC4

ACC3

DEC2

ACC2

ACC4

DEC2

DEC1

60.0S

100S

65.5S 55.0S 50.0S 72.0S 35.0S

0.1S

0.1S

Set
value
:16

Output signals from terminals Y1 to Y5

Ou

tp

u

t

fre

q

u

e

n

cy(m

o

to

r sp

e

e

d

)

Multistep
frequency 1
(Stage 1)

Multistep
frequency 2

Multistep
frequency 3

Multistep
frequency 4

Multistep
frequency 5

Multistep
frequency 6

Multistep
frequency 7
(Stage 7)

Set
value
:17

Running and stopping are controlled by pressing the

and keys and by opening and closing the control
terminals.
When using the keypad panel, pressing the key
starts operation. Pressing the key pauses stage
advance. Pressing the key again restarts operation
from the stop point according to the stages. If an alarm
stop occurs, press the key to release operation
of the inverter protective function, then press the
key to restart stage advance.
If required to start operation from the first stage "C22
Pattern operation (stage 1)," enter a stop command and
press the key.
If an alarm stop occurs, press the key to release
the protective function, then press the key again.

Notes:
1. The direction of rotation cannot be reversed by a
command issued from the key on the keypad panel
or terminal [REV]. Any reverse rotation commands entered
are canceled. Select forward or reverse rotation by the data
in each stage. When the control terminals are used for
operation, the self-hold function of operation command also
does not work. Select an alternate type switch when using.
2. At the end of a cycle, the motor decelerates-to-stop
according to the value set to "F08 Deceleration time 1."


This function selects the frequency setting method.








For the setting method, see the explanation for F01.




This function sets the Gain and Bias of the analog input

(terminals [12] ).

The setting range :

BIAS: -100 to +100%

GAIN:0.0 to 200%

Terminal
12

Gain

Bias

Reference
voltage

-10 0 +10[V]

Output value of Gain 12

Analog input voltage
[terminal 12]

200%

100%

50%

+10V

-10V

-10 0 +10[V]

Output value of Bias 12

Output value of Gain 12

Bias setting
(when positive)

Bias setting
(when negative)

+10V

(+100%)

-10V

(-100%)


C 3 1

B I A S

1 2

C 3 2

G A I N

1 2

C30

Frequency command 2

C31

Bias (terminal[12])

C32

Gain (terminal[12])

C33

Analog setting signal filter

Related functions

E01 to E09

(Set value:11)

F01

FWD

FWD

FWD

FWD

FWD

REV

STOP

STOP

RESET

RESET

RESET