EQ5 AC Drive Operations Manual

_______________________________________________________________________

TECO – Westinghouse Motor Company Serial Communications Modbus 117


Data format [12] Index data (ACC/DEC time, display coefficient):

15 14

13

12

11

10 9 8 7 6 5 4 3 2 1 0

Polarity

0

0

0 Index portion

Data portion

0: Positive (+),

0: 0.01 X

001–999

(0.00–9.99)

1: 0.1

X

100–999

(10.0–99.9)

1: Negative ( - )

2: 1

X

100–999

(100–999)

3: 10

X

100–999

(1000–9990)



Example: F07 (acceleration time 1) = 20.0 s

10.0 < 20< 99.9

→ index =1

20.0 = 0.1 X 200

→ 0400

H

+ 00C8

H

= 04C8

H

Data format [13] Pattern operation:

15 14

13

12

11

10 9 8 7 6 5 4 3 2 1 0

Direction

of

rotation

0

Time

Index portion

Data portion


0: 1st ACC/DEC time

0: 0.01 X

001–999

(0.00–9.99)

0: FWD

1: 2nd ACC/DEC time

1: 0.1

X

100–999

(10.0–99.9)

1: REV

2: 3rd ACC/DEC time

2: 1

X

100–999

(100–999)

3: 4th ACC/DEC time

3: 10

X

100–999

(1000–9990)

Example: C22 (Stage1) = 10.0s R2 (10s, reverse rotation, acceleration time 2/deceleration time 2)
Since 10.0 = 0.1 X 100 > 9000

H

+ 0400

H

+ 0064

H

= 9464

H


Data format [14] Operation command:

15

14

13

12

11

10 9 8 7 6 5 4 3 2 1 0

RST 0 0 0 0 X9 X8 X7 X6 X5 X4 X3 X2 X1 REV

FWD

(All bit are ON by 1)
Example: S06 (operation command) = FWD, X1 and X5 = ON

0000 0000 0100 0101

b

= 0045

H


Data format [15] Universal output terminal:

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

0 0 0 0 0 0 0 0 0 0 0 Y5

Y4

Y3

Y2

Y1

(All bit are ON by 1)
Example: M15 (Universal output terminal)=Y1 and Y5 = ON

0000 0000 0001 0001

b

= 0011

H

This manual is related to the following products: