beautypg.com

HP Anab EQ5 User Manual

Page 120

background image

EQ5 AC Drive Operations Manual

_______________________________________________________________________

TECO – Westinghouse Motor Company Serial Communications Modbus 114

Function data Registers

Address

Code

Name

Unit

Variable Range

Min.
Unit

Read/

Write

Data

Format

1800 S08

Acceleration time F07

s

0.1–3600.0

0.1 R/W

3

1801 S09

Deceleration time F08

s

0.1–3600.0

0.1 R/W

3

1802 S10

Torque limit level 1
(driving) F40

%

20.00 –200.00, 999
(EQ5:20.00-150.00)

1.00 R/W

5

1803 S11

Torque limit level 2
(braking) F41

%

0.00, 20.00–200.00, 999
(EQ5:20.00-150.00)

1.00 R/W

5


Notes: 1) The writing of data out of range is treated as out of range error.

2) Use a value of 7FFF

H

to enter 999 for torque limit functions.

Monitoring parameter registers

Address Code

Description

Unit

Range

Min.

Unit

Read/Write

Data

Format

2049 M01

Frequency command
(final command)

-

- 20000–20000
(max. frequency at ±
20000)

1 R [2]

2053 M05

Frequency command
(final command)

Hz 0.00-120.00)

0.01

R

[5]

2054 M06

Actual frequency

-

- 20000–20000
(max. frequency at ±
20000)

1 R [2]

2055

M07 Actual torque value

%

- 200.00–200.00 0.01

R [6]

2056

M08 Torque current

%

- 200.00–200.00 0.01

R [6]

2057 M09

Output

frequency

Hz

0.00-120.00)

0.01

R

[5]

2058 M10

Motor output (input
electric power)

%

0.00–200.00

0.01 R

[5]

2059 M11

Output current r. m. s.

%

0.00–200.00 (inverter
rating at 100.00)

0.01 R

[5]

2060

M12 Output voltage r. m. s.

V

0.0–600.0 1.0

R

[3]

2061 M13

Operation command
(final command)

-

Refer to data format
[14]

- R [14]

2062 M14

Operating state

-

Refer to data format
[16]

- R [16]

2063 M15

Universal output
terminal data

-

Refer to data format
[15]

- R [15]

2064

M16 Fault memory 0

-

Refer to data format
[10]

- R [10]

2065

M17 Fault memory 1

2066

M18 Fault memory 2

2067

M19 Fault memory 3

2068 M20

Integrated operating
time

h

0–65535

1 R [1]

2069

M21 DC link voltage

V

0–1000 1

R

[1]

2071 M23

Type code

-

Refer to data format
[17]

- R [17]

2072 M24

Inverter capacity code

-

Refer to data format
[11]

- R [11]


Cont.

This manual is related to the following products: