HP Anab EQ5 User Manual
Page 122
EQ5 AC Drive Operations Manual
_______________________________________________________________________
TECO – Westinghouse Motor Company Serial Communications Modbus 116
Data format [6] Decimal data (Positive, negative): Min. unit 0.01
Example: M07 (actual torque value)= - 85.38% - 85.38 X 100= - 8538=DEA6
H
Data format [7] Unsigned Decimal data (Positive): Min. unit 0.001
Example: If o05 (follow - up side ASR 1 constant) = 0.105s 0.105 X 1000 = 105 =
0069
H
Data format [8] Decimal data (Positive, negative): Min. unit 0.001
Example: Data = -1.234 - 1.234 X 1000 = - 1234 = FB2E
H
Data format [9] Unsigned Integer data (Positive): Min. unit 2
Example If P01 (Motor 1 number of poles) =2pole 2 = 0002
H
Data format [10] Alarm code:
Code
Description
Code
Description
0
No alarm
-
22
Overheat, DB resistor
dbH
1
Overcurrent, during acceleration (INV output )
OC1
23
Overload, motor 1
OL1
2
Overcurrent, during deceleration (INV output )
OC2
24
Overload, motor 2
OL2
3
Overcurrent, during steady state operation
(INV output )
OC3 25 Overload,
inverter
OLU
5 Ground
fault
EF 27 Overspeed
OS
6
Overvoltage, during acceleration
OU1
28
PG wire break
Pg
7
Over voltage, during deceleration
OU2
31
Memory error
Er1
8
Overvoltage, during steady state operation OU3 32
Keypad
error
Er2
10
DC undervoltage
LU
33
CPU error
Er3
11
Power supply open phase
Lin
34
Option comm. error
Er4
14
Blown DC fuse
FUS
35
Option error
Er5
16
Output wiring error
Er7
36
PL error
Er6
17
Overheat, heat sink, inverter
OH1
37
Output wiring error
Er7
18
Overheat, outside thermal
OH2
38
RS-485 comm. error
Er8
19
Overheat, unit inside temp.
OH3
Data format [11] Capacity code:
Code
Capacity
(HP)
Code
Capacity
(HP)
Code
Capacity
(HP)
7 0.07(spare)
2000
20 20000 200
15 0.15(spare)
2500
25
25000 250
25 0.25
3000 30 30000
300
50 0.5
4000 40
35000
350
100 1 5000
50
40000
400
200 2 6000
60
45000
450
300 3 7500
75
50000
500
500
5 10000 100 60600 600
750 7.5 12500 125 60700 700
1000 10 15000 150 60800 800
1500 15 17500
175