Yaskawa GPD503 Drive User Manual
Page 95

B. KEYPAD KEYS - Continued
LABEL
FUNCTION
>
IN DRIVE MODE OR PROGRAM MODE: When a changeable constant
RESET
setting value is being displayed, pressing this key moves the blinking
(i.e. "changeable") position to the next digit to the right. If at the right-most
position, this will wrap-around to the first "changeable" position on the
left side of the display.
IN DRIVE MODE ONLY: When a GPD 503 fault has occurred, pressing
this key will reset the fault circuit in the GPD 503. Pressing this key along
with the DSPL key will allow access to the Sn- and Cn- constants lists (for
READING ONLY of the constant settings).
^
IN DRIVE MODE OR PROGRAM MODE: Pressing this key will increase
the value of the blinking digit in the display by 1. Increasing stops at the
value of
9 , or F. Pressing this key will scroll up by 1 within a constants list.
v
IN DRIVE MODE OR PROGRAM MODE: Pressing this key will decrease
the value of the blinking digit in the display by 1. Decreasing stops at the
value of
0. Pressing this key will scroll down by 1 within a constants list.
POWER
PRESS
PRESS
ON
RUN KEY
STOP KEY
RUN
COMMAND
FREQUENCY
REFERENCE
OUTPUT
FREQUENCY
RUN
LAMP
STOP
LAMP
= Off
= Blinking
= Lighted Steady
Figure 3-2. Functioning of RUN and STOP Lamps
Table 3-1. Digital Operator Controls - Continued
B. KEYPAD KEYS - Continued
LABEL
FUNCTION
3-3