beautypg.com

Yaskawa GPD503 Drive User Manual

Page 116

background image

TROUBLESHOOTING CHART 7.2

MOTOR STALLS DURING ACCELERATION

ACCELERATION TIME

TOO SHORT?

YES

YES

YES

YES

YES

WITH GPD 503 IN
STOPPED CONDITION,
EXTEND ACCELER-
ATION TIME BY
REPROGRAMMING
bn-01 OR bn-03.

NO

NO

NO

NO

NO

LOAD TORQUE

TOO HIGH?

LOAD

INERTIA
LARGE?

CHECK IF SPECIAL
MOTOR IS USED.

V/F SELECTION

APPROPRIATE?

WITH GPD 503 IN
STOPPED CONDITION,
SET OPTIMUM V/F BY
REPROGRAMMING
Sn-02.

LARGE MOTOR

TERMINAL

VOLTAGE DROP?

- USE LARGER WIRE

BETWEEN GPD 503
AND MOTOR.

- SHORTEN WIRING

DISTANCE BETWEEN
GPD 503 AND MOTOR.

- DECREASE LOAD

INERTIA.

- EXTEND ACCEL-

ERATION TIME BY
REPROGRAMMING
bn-01 OR bn-03.

- DECREASE LOAD

TORQUE.

- REPLACE GPD 503

WITH ONE OF LARGER
CAPACITY.

7-4