Yaskawa GPD503 Drive User Manual
Page 102

ACTION
DESCRIPTION
DISPLAY
Press PRGM Key
DRIVE lamp lights. Display shows the
DRIVE
Frequency Reference value as set by
to Return to
input at terminal 13, 14, or 16, ref.
(no digit
Drive Mode
terminal 17.
blinking)
Set Auto/Manual
Display shows frequency reference
Switch, If Used,
commanded by the present level of the
To Select Desired
input signal.
(no digit
External
blinking)
Reference Signal
Adjust External
Observe display as speed reference is
Speed Reference
adjusted. Stop when display shows
To Desired Level
desired output frequency.
(no digit
EXAMPLE: Adjust for 60Hz output.
blinking)
Press DSPL Key
Present Output Frequency is
to Show Present
displayed.
Output Frequency
Close Contact
Check motor operation at programmed
at Terminals
Jog Frequency operating speed.
7 & 11 To
Jog Motor
Close Contact
GPD 503 output increases to Frequency
at Terminals 1
Reference level, at programmed Accel Rate.
& 11 To Perform
Motor speed increases accordingly.
Forward Run
Open Contact
Motor speed decreases under GPD 503
at Terminals 1
control, at preset Decel Rate, to zero.
& 11 To Stop
Drive
F 6 0.0 0
0.0 0
6.0 0
6 0.0 0
0.0 0
F 0 0.0 0
F 0 0.0 0
3-10