A1-4 – Yaskawa GPD503 Drive User Manual
Page 128

CONSTANT
SET
FACTORY
USER
PARA.
NUMBER
DATA NAME
DIGIT
DATA
FUNCTION
SETTING
SETTING
REF.
Sn-06 Operation Mode
XXXX
00 = S-curve at Accel/Decel,
0000
2.27
Select 3
with 0.2 second delay
01 = S-curve at Accel/Decel
disabled
10 = S-curve at Accel/Decel,
with 0.5 second delay
11 = S-curve at Accel/Decel,
with 1.0 second delay
XXXX
0
Output frequency propor-
2.3
tional to Auto reference
1
Output frequency inversely
proportional to Auto ref.
XXXX
0
Auto Reference - Loss
2.4
Detection disabled
1
Auto Reference - Loss
Detection enabled
Sn-07 Overtorque
XXXX
0
Overtorque detection is
0000
2.22
Detection
disabled
1
Overtorque detection is
enabled
XXXX
0
Detects only during set
frequency
1
Detects during all
frequency conditions
XXXX
0
Operation continues after
overtorque detection
1
Coasts to stop when over-
torque is detected
XXXX
– Not
Used
Sn-08 Option Ref-
XXXX
0
Operated from installed
0100
See
erence Select
option
Option
1
Operated from Digital
Instructions
Operator and/or
external terminals
XXXX
0
Run/Stop from installed
option card
1
Run/Stop from Digital
Operator and/or
external terminals
Table A1-3. System Constants (Sn-XX) - Continued
CONSTANT
SET
FACTORY USER
PARA.
NUMBER DATA NAME DIGIT DATA
FUNCTION
SETTING SETTING
REF.
A1-4