2.4 AUTO REFERENCE - LOSS DETECTION

Sn-06: Operation Mode

Digit 4 [ X X X X ] : Auto Reference

Select 3

Loss Detection

Factory setting:

0

X X X (disabled)

The reference loss detection function is either enabled or disabled, based on the setting of
Sn-06 X X X X. When enabled (

1

X X X ), the reference loss detection compares the

change in reference with respect to time (0.4 seconds). If longer than 0.4 seconds, the
GPD 503 will decelerate to the set reference; if shorter than 0.4 seconds, the GPD 503 will
continue to operate at 80% of the output frequency. To regain control of output
frequency, either exceed the set reference (80% of reference) or initiate a STOP command.
(If Auto Reference is less than Fmax (Cn-02) x .05, then this function is not performed.)

FWD RUN

COMMAND

AUTO

REFERENCE

GPD 503
OUTPUT

FREQUENCY

80%
REF

10%

80%
FREQ.

0.4 SEC

0.4 SEC

Time Chart

2-5