beautypg.com

Appendix 1. listing of constants, Frequency reference memory settings (an-xx), A1-1 – Yaskawa GPD503 Drive User Manual

Page 125: Run operative settings (bn-xx)

background image

Appendix 1. LISTING OF CONSTANTS

The GPD 503 control circuits use five types of constants to select functions and character-
istics of the GPD 503. Changing of constant settings must be done in the Program mode,
unless otherwise indicated.

1. Frequency Reference Memory Settings (An-XX) (

settings can be changed at any time

)

2. Run Operative settings (bn-XX) (

settings can be changed at any time

)

3. System constants (Sn-XX)
4. Control constants (Cn-XX)
5. Monitor Display (Un-XX) (

monitor selection only; not programmable by user

)

The following tables list all constants of each type in numerical order. For each constant,
reference paragraph(s) in Section 2 are listed (if applicable) where the features of the
GPD 503 affected by that constant are described.

CONSTANT INCRE-

SETTING

FACTORY

USER

PARA.

NUMBER

DATA NAME

MENT

RANGE

SETTING SETTING

REF.

An-01

Frequency Reference 1

0.01 Hz 0.00 - 400.00

0.00

2.24

An-02

Frequency Reference 2

0.01 Hz 0.00 - 400.00

0.00

2.24

An-03

Frequency Reference 3

0.01 Hz 0.00 - 400.00

0.00

2.24

An-04

Frequency Reference 4

0.01 Hz 0.00 - 400.00

0.00

2.24

An-05

Frequency Reference 5

0.01 Hz 0.00 - 400.00

0.00

2.24

An-06

Frequency Reference 6

0.01 Hz 0.00 - 400.00

0.00

2.24

An-07

Frequency Reference 7

0.01 Hz 0.00 - 400.00

0.00

2.24

An-08

Frequency Reference 8

0.01 Hz 0.00 - 400.00

0.00

2.24

An-09

Jog Reference

0.01 Hz 0.00 - 400.00

6.00

2.15, 2.24

Table A1-1. Frequency Reference Memory Settings (An-XX)

CONSTANT

INCRE-

SETTING FACTORY USER PARA.

NUMBER

DATA NAME

MENT RANGE

SETTING SETTING

REF.

A1-1