2.22 OVERTORQUE DETECTION Continued

Sn-19: Multi-function Analog

Data

04

: External Overtorque

Input (Term. 16)

Detection Level Adjustment

The multi-function analog input at terminal 16 may be configured to allow analog control
of the overtorque detection level. When this function is programmed into Sn-19, the
internal overtorque detection level (Cn-26) is disabled.

Sn-20: Multi-function Output 1 – Contact

Data

0b

: Overtorque

(terminals 9 & 10)

Detection

Sn-21: Multi-function Output 2 – Open Collector

(terminals 25 & 27)

Sn-22: Multi-function Output 3 – Open Collector

(terminals 26 & 27)

A contact, or two open collector outputs, can be programmed to change states during an
overtorque detection condition.

1R

GPD 503

15 +15V

16 0-10V (20 K

1

)

17

C

OVERTORQUE

DETECTION

LEVEL

200%

OVERTORQUE

DETECTION

LEVEL

0%

0V

10V

VOLTAGE REFERENCE

2-32