TROUBLESHOOTING CHART 7.6
OVERLOAD (
oL
) FAULT INDICATION
LOAD TOO LARGE
(MOTOR OVERHEATED)?
YES
YES
YES
YES
YES
YES
DECREASE LOAD
WITHIN RATING.
CHECK MOTOR
AND LOAD.
NOTIFY
FACTORY.
NO
NO
NO
NO
NO
NO
V/F SELECTION
APPROPRIATE?
WITH GPD 503 IN
STOPPED CONDITION,
REPROGRAM Sn-02 TO
PROPER V/f PATTERN.
YES
NO
MORE THAN ONE
MOTOR ON THE
GPD 503?
WITH GPD 503 IN STOPPED
CONDITION, REPROGRAM
Sn-14 TO X X X
1 TO DISABLE
THERMAL MOTOR OVERLOAD
PROTECTION CIRCUIT. THEN
INSTALL A THERMAL RELAY
OR THERMAL PROTECTOR
FOR EACH MOTOR.
WITH GPD 503 IN
STOPPED CONDITION,
REPROGRAM Cn-09.
IS GPD 503 CAPACITY
(Sn-01) FACTORY SET
CORRECTLY?
IS ELECTRONIC THERMAL
OVERLOAD (Cn-09)
SET CORRECTLY?
DISCONNECT WIRING FROM
OUTPUT TERMINALS T1 (U),
T2 (V) AND T3 (W). IS OL
STILL INDICATED?
REMOVE NOISE SOURCE:
• CONNECT SURGE
SUPPRESSOR TO RELAY
AND MAGNETIC CON-
TACTOR COILS.
• PROVIDE LINE FILTER
TO REMOVE NOISE ON
INPUT POWER LINE.
CONTROL PCB OR BASE
DRIVE PCB IS FAULTY.
REPLACE FAULTY BOARD.
ERRONEOUS OPERATION
DUE TO NOISE?
7-8
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)