beautypg.com

Yaskawa GPD503 Drive User Manual

Page 120

background image

TROUBLESHOOTING CHART 7.6

OVERLOAD (

oL

) FAULT INDICATION

LOAD TOO LARGE

(MOTOR OVERHEATED)?

YES

YES

YES

YES

YES

YES

DECREASE LOAD
WITHIN RATING.

CHECK MOTOR
AND LOAD.

NOTIFY

FACTORY.

NO

NO

NO

NO

NO

NO

V/F SELECTION

APPROPRIATE?

WITH GPD 503 IN
STOPPED CONDITION,
REPROGRAM Sn-02 TO
PROPER V/f PATTERN.

YES

NO

MORE THAN ONE

MOTOR ON THE

GPD 503?

WITH GPD 503 IN STOPPED
CONDITION, REPROGRAM
Sn-14 TO X X X

1 TO DISABLE

THERMAL MOTOR OVERLOAD
PROTECTION CIRCUIT. THEN
INSTALL A THERMAL RELAY
OR THERMAL PROTECTOR
FOR EACH MOTOR.

WITH GPD 503 IN
STOPPED CONDITION,
REPROGRAM Cn-09.

IS GPD 503 CAPACITY
(Sn-01) FACTORY SET

CORRECTLY?

IS ELECTRONIC THERMAL

OVERLOAD (Cn-09)

SET CORRECTLY?

DISCONNECT WIRING FROM

OUTPUT TERMINALS T1 (U),

T2 (V) AND T3 (W). IS OL

STILL INDICATED?

REMOVE NOISE SOURCE:

• CONNECT SURGE
SUPPRESSOR TO RELAY
AND MAGNETIC CON-
TACTOR COILS.

• PROVIDE LINE FILTER
TO REMOVE NOISE ON
INPUT POWER LINE.

CONTROL PCB OR BASE
DRIVE PCB IS FAULTY.
REPLACE FAULTY BOARD.

ERRONEOUS OPERATION

DUE TO NOISE?

7-8