Appendix 3. gpd 503 capacity, A3-1 – Yaskawa GPD503 Drive User Manual
Page 142

Appendix 3. GPD 503 CAPACITY
System Constant Sn-01 (GPD 503 Capacity) is factory preset per the voltage and horse-
power ratings of the GPD 503. Table A3-1 identifies the set value, per Model Number. If
the Control PCB is replaced, the new board MUST have Sn-01 programmed to the
appropriate set value BEFORE again operating the GPD 503 in the Drive mode.
HP
Motor Rated Current
Reference Current For
Sn-01
Rating
Max Motor Output Current (Amps) (Cn-09)
Setting Constants (Amps)
Set Value (CT)
HP - (KW)
(See Note 1)
(See Note 2)
2 3 0 V
01
DS305 1
(0.75)
3.3
4.8
02
DS302 2
(1.5)
6.1
6.4
03
DS306 3
(2.2)
8.5
9.6
04
DS307 5
(3.7)
14.1
16
05
DS308 7.5
(5.5)
20.7
24
06
DS309 10
(7.5)
27.5
32
07
DS310 15
(11)
39.7
48
08
DS311 20
(15)
53.0
64
09
DS322 25
(18.5)
65.8
80
0A
DS323 30
(22)
77.2
96
0b
DS2040
40
(30)
105
130
0b GPD503-2L40
40/50
(30)
105
130
0C
DS2050
50
(37)
131
160
0C GPD503-2L50
60
(37)
131
160
0d
DS2060
60
(45)
156
183
0d GPD503-2L60
60
(45)
156
183
0E
DS2075
75
(55)
190
224
0E GPD503-2L75
75
(55)
190
224
0F
DS2100
100
(75)
240
300
0F GPD503-2L100
100
(75)
240
300
4 6 0 V
21
DS313
1
(0.75)
1.7
2.6
22
DS304
2
(1.5)
3.1
4.0
23
DS314
3
(2.2)
4.2
4.8
24
DS315
5
(3.7)
6.8
8.0
25
DS316
7.5
(5.5)
10.2
12
26
DS317
10
(7.5)
13.4
16
27
DS318
15
(11)
20.1
24
28
DS326
20
(15)
26.7
32
29
DS325
25
(18.5)
33.4
40
2A
DS330
30
(22)
38.5
48
2b
DS340
40
(30)
52.5
64
See NOTES on next page.
Table A3-1. GPD 503 Capacity
Drive
Motor Rated Current GPD 503 Rated Current
Sn-01 Model Max Motor Output
(Amps) (Cn-09)
(Amps) (
Reference Current For
Set Value No.
HP - (kW)
(See Note 1)
Setting Constants;
See Note 2)
A3-1
( "L" ) (04/27/95)