Yaskawa GPD503 Drive User Manual
Page 18

1-2.4
SECTION A. 230V
TERMINAL
FUNCTION
1 HP
3 TO 40 HP
L1 (R)
Three phase Main circuit input power supply
L2 (S)
200 / 208 / 220V at 50 Hz; 200 / 208 / 220 / 230V at 60 Hz
L3 (T)
T1 (U)
Three phase AC output to motor
T2 (V)
0V to max. input voltage level
T3 (W)
l
1 (r)
Power for heat sink fan
l
2 (
s
)
– – – – – –
200-230 Vac, single phase – two lines from input power
B0/–
– – – – – –
DB Unit terminals *
B1/+
DB Unit terminals (B1/+ & B2) *
DC bus terminals
– – – – – –
B2
– [ – (N) ]** DC bus terminals (B1/+ & –)
– – – – – –
+3 (P3)
DB Unit terminals (+1 & –)
+1 (P1)
[ (+3 & –) ]**
– – – – – –
DC bus terminals (+1 & –)
[ (+3 & – ) ]**
x
Power supply output for
y
– – – – – –
options (220 Vac, 30 VA)
G (E)
Ground terminal (100 ohms or less)
SECTION B. 460V
TERMINAL
FUNCTION
1 TO 60 HP
L1 (R)
Three phase Main circuit input power supply
L2 (S)
380 / 400 / 415 / 460V at 50/60 Hz
L3 (T)
T1 (U)
Three phase AC output to motor
T2 (V)
0V to max. input voltage level
T3 (W)
l
2 (
s
)
Power for heat sink fan
– – – – –
l
1 (r)
– – – – –
230 Vac single phase
Power for heat sink fan:
l
2 200 (
s
200)
l
1 to
l
2 200: 230 Vac
l
2 400 (
s
400)
– – – – –
l
1 to
l
2 400: 460 Vac
B0/–
– – – – –
DB Unit Terminals *
B1/+
DB Unit terminals
DB Unit terminals
DC bus terminals
– – – – –
B2
(B1/+ & B2) *
(B1/+ & B2)
– [ – (N) ]**
DC bus terminals
DC bus terminals
– – – – –
DB Unit Terminals
(B1/+ & –)
(B1/+ & B0/–)
(+1 & –) * [ (+3 & –) ]**
+3 (P3)
DC bus terminals
+1 (P1)
– – – – –
(+1 & –) [ (+3 & –) ]**
x
Power supply output for
y
– – – – –
options (220 Vac, 30 VA)
G (E)
Ground terminal (100 ohms or less)
SECTION A. 230V
FUNCTION
TERMINAL
1 - 10HP (CT) 15 - 30HP (CT)
40 - 100HP (CT)
SECTION B. 460V
FUNCTION
TERMINAL
1 - 10HP (CT) 15 - 20HP (CT) 25 - 60HP (CT) 75 - 400HP (CT)
Table 1-2. Terminal Functions and Voltages of Main Circuit
– – – – – indicates that terminals are not present.
* For installation of DB (Dynamic Braking) Units, see Appendix 7.
** indicates terminal marking or connection difference for units with "L" in Model No.
( "L" ) (04/27/95)