B. Drive Operation From Digital Operator (Using Factory Settings):
ACTION
DESCRIPTION
DISPLAY
Apply Power
DRIVE lamp is on.
The Frequency Reference (An-01) set
value appears.
Use
>
,
^
,
Blinking position of display shifts to the
and
v
Keys
left. Value of blinking digit increases
as Necessary
or decreases when keys are pressed.
Until Display
Shows Desired
Run Frequency
Press DATA Key
Displayed value stops blinking for approx-
ENTER
imately 2 seconds, then digit resumes
To Write New
blinking.
Value Into
Memory
Press FWD Key
Observe FWD and REV indicator lamps on
FWD REV
REV
Digital Operator to see which direction
To Select Desired
motor will rotate when GPD 503 is started.
Direction of
EXAMPLE:
Motor Rotation
FWD Run
selected
Press DSPL Key
Present Output Frequency is
displayed.
Press and Hold
Check motor operation at programmed
JOG Key
Jog Frequency operating speed.
Release JOG
GPD 503 output increases to Frequency
Key; Press
Reference level, at programmed Accel Rate.
RUN Key
Motor speed increases accordingly.
Press STOP Key
Motor speed decreases under GPD 503
control, at preset deceleration rate, to zero.
Motor remains stopped.
F 0 0.0 0
F 6 0.0 0
F 6 0.0 0
F 6 0.0 0
0.0 0
0.0 0
6.0 0
6 0.0 0
3-8