beautypg.com

2 pr eset ting aut o matically – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual

Page 98

background image

98

3 Touch Probe Cycles for Automatic Workpiece Inspection

3.2 Pr

eset

ting aut

o

matically

Datum number in table

Q305: Enter the number in the

datum or preset table in which the TNC is to save the
coordinate. If you enter Q305=0, the TNC
automatically sets the display so that the new datum
is on the probed surface.

New datum for touch probe axis

Q333 (absolute):

Coordinate in the touch probe axis at which the TNC
should set the datum. Basic setting = 0

Measured-value transfer (0, 1)

Q303: Specify

whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use. Is entered by the TNC when old
programs are read in (see “Saving the calculated
datum” on page 69).
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).

Example: NC blocks

5 TCH PROBE 417 DATUM IN TS AXIS

Q263=+25

;1ST POINT 1ST AXIS

Q264=+25

;1ST POINT 2ND AXIS

Q294=+25

;1ST POINT 3RD AXIS

Q320=0

;SET-UP CLEARANCE

Q260=+50

;CLEARANCE HEIGHT

Q305=0

;NO. IN TABLE

Q333=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER