2 pr eset ting aut o matically – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual
Page 75

HEIDENHAIN iTNC 530
75
3.2 Pr
eset
ting aut
o
matically
Measured-value transfer (0, 1)
Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).
Probe in TS axis
Q381: Specify whether the TNC
should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis
Probe TS axis: Coord. 1st axis
Q382 (absolute):
Coordinate of the probe point in the reference axis of
the working plane at which point the reference point
is to be set in the touch probe axis. Only effective if
Q381 = 1.
Probe TS axis: Coord. 2nd axis
Q383 (absolute):
Coordinate of the probe point in the minor axis of the
working plane at which point the reference point is
to be set in the touch probe axis. Only effective if
Q381 = 1.
Probe TS axis: Coord. 3rd axis
Q384 (absolute):
Coordinate of the probe point in the touch probe axis,
at which point the reference point is to be set in the
touch probe axis. Only effective if Q381 = 1.
New datum for touch probe axis
Q333 (absolute):
Coordinate in the touch probe axis at which the TNC
should set the datum. Basic setting = 0
Example: NC blocks
5 TCH PROBE 409 SLOT CENTER STUD
Q321=+50
;CENTER 1ST AXIS
Q322=+50
;CENTER 2ND AXIS
Q311=25
;RIDGE WIDTH
Q272=1
;MEASURING AXIS
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q305=10
;NO. IN TABLE
Q405=+0
;DATUM
Q303=+1
;MEAS. VALUE TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+85
;1ST CO. FOR TS AXIS
Q383=+50
;2ND CO. FOR TS AXIS
Q384=+0
;2RD CO. FOR TS AXIS
Q333=+1
;DATUM