beautypg.com

2 pr eset ting aut o matically – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual

Page 81

background image

HEIDENHAIN iTNC 530

81

3.2 Pr

eset

ting aut

o

matically

Measured-value transfer (0, 1)

Q303: Specify

whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use. Is entered by the TNC when old
programs are read in (see “Saving the calculated
datum” on page 69).
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).

Probe in TS axis

Q381: Specify whether the TNC

should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis

Probe TS axis: Coord. 1st axis

Q382 (absolute):

Coordinate of the probe point in the reference axis of
the working plane at which point the reference point
is to be set in the touch probe axis. Only effective if
Q381 = 1.

Probe TS axis: Coord. 2nd axis

Q383 (absolute):

Coordinate of the probe point in the minor axis of the
working plane at which point the reference point is
to be set in the touch probe axis. Only effective if
Q381 = 1.

Probe TS axis: Coord. 3rd axis

Q384 (absolute):

Coordinate of the probe point in the touch probe axis,
at which point the reference point is to be set in the
touch probe axis. Only effective if Q381 = 1.

New datum for touch probe axis

Q333 (absolute):

Coordinate in the touch probe axis at which the TNC
should set the datum. Basic setting = 0

Example: NC blocks

5 TCH PROBE 411 DATUM OUTS. RECTAN.

Q321=+50

;CENTER 1ST AXIS

Q322=+50

;CENTER 2ND AXIS

Q323=60

;FIRST SIDE LENGTH

Q324=20

;SECOND SIDE LENGTH

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q305=0

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;2RD CO. FOR TS AXIS

Q333=+1

;DATUM