beautypg.com

3 a u to matic w o rk piece measur ement – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual

Page 120

background image

120

3 Touch Probe Cycles for Automatic Workpiece Inspection

3.3 A

u

to

matic W

o

rk

piece Measur

ement

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:
0: No measuring log
1: Generate measuring log: with the standard setting
the TNC saves the log file TCHPR421.TXT in the
directory in which your measuring program is also
stored.
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.

PGM stop if tolerance error

Q309: Definition of

whether in the event of a violation of tolerance limits
the TNC is to interrupt the program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message

Tool number for monitoring

Q330: Definition of

whether the TNC is to monitor the tool (see “Tool
monitoring” on page 112)
0: Monitoring not active
>0: Tool number in the tool table TOOL.T

No. of measuring points (4/3)

Q423: Specify

whether the TNC should measure the stud with 4 or
3 probing points:
4: Use 4 measuring points (standard setting)
3: Use 3 measuring points (standard setting)

Example: NC blocks

5 TCH PROBE 421 MEASURE HOLE

Q273=+50

;CENTER 1ST AXIS

Q274=+50

;CENTER 2ND AXIS

Q262=75

;NOMINAL DIAMETER

Q325=+0

;STARTING ANGLE

Q247=+60

;STEPPING ANGLE

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=1

;MOVE TO CLEARANCE

Q275=75.12

;MAX. LIMIT

Q276=74.95

;MIN. LIMIT

Q279=0.1

;TOLERANCE 1ST CENTER

Q280=0.1

;TOLERANCE 2ND CENTER

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL NUMBER

Q423=4

;NO. OF MEAS. POINTS