beautypg.com

Saving the basic rotation in the preset table, Displaying a basic rotation, To cancel a basic rotation – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual

Page 36: 3 compensating w o rk piece misalignment

background image

36

2 Touch probe cycles in the Manual and Electronic Handwheel modes

2.3 Compensating W

o

rk

piece Misalignment

Saving the basic rotation in the preset table

After the probing process, enter the preset number in which the
TNC is to save the active basic rotation in the Number in table:
input box.

Press the ENTRY IN PRESET TABLE soft key to save the basic
rotation in the preset table.

Displaying a basic rotation

The angle of the basic rotation appears after ROTATION ANGLE
whenever PROBING ROT is selected. The TNC also displays the
rotation angle in the additional status display (STATUS POS.).

In the status display a symbol is shown for a basic rotation whenever
the TNC is moving the axes according to a basic rotation.

To cancel a basic rotation

Select the probe function by pressing the PROBING ROT soft key.

Enter a rotation angle of zero and confirm with the ENT key.

Terminate the probe function by pressing the END key.