4 special cy cles – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual
Page 153

HEIDENHAIN iTNC 530
153
3.4 Special Cy
cles
Parameter number for result:
Enter the number of
the Q parameter to which you want the TNC to assign
the first coordinate (X).
Relative measuring path in X:
X component of the
direction vector defining the direction in which the
touch probe is to move.
Relative measuring path in Y:
Y component of the
direction vector defining the direction in which the
touch probe is to move.
Relative measuring path in Z:
Z component of the
direction vector defining the direction in which the
touch probe is to move.
Maximum measuring path:
Enter the maximum
distance from the starting point by which the touch
probe may move along the direction vector.
Feed rate:
Enter the measuring feed rate in mm/min.
Maximum retraction path:
Traverse path in the
direction opposite the probing direction, after the
stylus was deflected.
REFERENCE SYSTEM (0=ACT/1=REF):
Specify whether
the result of measurement is to be saved in the actual
coordinate system (ACT, can therefore be shifted or
rotated), or with respect to the machine coordinate
system (REF).
Example: NC blocks
5 TCH PROBE 4.0 MEASURING IN 3-D
6 TCH PROBE 4.1 Q1
7 TCH PROBE 4.2 IX-0.5 IY-1 IZ-1
8 TCH PROBE
4.3 DIST +45 F100 MB50 REFERENCE SYSTEM:0