2 pr eset ting aut o matically – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual
Page 79

HEIDENHAIN iTNC 530
79
3.2 Pr
eset
ting aut
o
matically
DATUM FROM OUTSIDE OF RECTANGLE
(touch probe cycle 411, DIN/ISO: G411)
Touch probe cycle 411 finds the center of a rectangular stud and
defines its center as datum. If desired, the TNC can also enter the
coordinates into a datum table or the preset table.
1
The TNC positions the touch probe to the starting points at rapid
traverse (value from MP6150 or MP6361) following the positioning
logic (see “Running touch probe cycles” on page 26) to the
starting point
1
. The TNC calculates the probe starting points from
the data in the cycle and the safety clearance from MP6140.
2
Then the touch probe moves to the entered measuring height and
probes the first touch point at the probing feed rate (MP6120 or
MP6360).
3
Then the touch probe moves either paraxially at the measuring
height or linearly at the clearance height to the next starting point
2
and probes the second touch point.
4
The TNC positions the probe to starting point
3
and then to starting
point
4
to probe the third and fourth touch points.
5
Finally the TNC returns the touch probe to the clearance height and
processes the determined datum depending on the cycle
parameters Q303 and Q305. (see “Saving the calculated datum”
on page 69)
6
If desired, the TNC subsequently measures the datum in the touch
probe axis in a separate probing and saves the actual values in the
following Q parameters.
X
Y
1
2
4
3
Parameter number
Meaning
Q151
Actual value of center in reference axis
Q152
Actual value of center in minor axis
Q154
Actual value of length in the reference
axis
Q155
Actual value of length in the minor axis
Before programming, note the following
To prevent a collision between the touch probe and
workpiece, enter high estimates for the lengths of the 1st
and 2nd sides.
Before a cycle definition you must have programmed a