1 measur ing w o rk piece misalignment – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual
Page 61

HEIDENHAIN iTNC 530
61
3.1 Measur
ing W
o
rk
piece Misalignment
Setting a BASIC ROTATION (touch probe
cycle 404, DIN/ISO: G404)
With touch probe cycle 404, you can set any basic rotation
automatically during program run. This cycle is intended primarily for
resetting a previous basic rotation.
Preset value for basic rotation:
Angular value at
which the basic rotation is to be set.
Example: NC blocks
5 TCH PROBE 404 BASIC ROTATION
Q307=+0
;PRESET BASIC ROTATION