4 special cy cles – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual
Page 151

HEIDENHAIN iTNC 530
151
3.4 Special Cy
cles
Parameter number for result:
Enter the number of
the Q parameter to which you want the TNC to assign
the first measured coordinate (X). The values Y and Z
are in the immediately following Q parameters.
Probing angle:
Enter the angle in whose direction the
probe is to move and confirm with the ENT key.
Probing angle:
Angle, measured from the probing
axis
at which the touch probe is to move. Confirm
with ENT
Maximum measuring path:
Enter the maximum
distance from the starting point by which the touch
probe is to move. Confirm with ENT.
Feed rate:
Enter the measuring feed rate in mm/min.
Maximum retraction path:
Traverse path in the
direction opposite the probing direction, after the
stylus was deflected. The TNC returns the touch
probe to a point no farther than the starting point, so
that there can be no collision.
REFERENCE SYSTEM (0=ACT/1=REF):
Specify whether
the result of measurement is to be saved in the actual
coordinate system (ACT, can therefore be shifted or
rotated), or with respect to the machine coordinate
system (REF).
Error mode (0=OFF/1=ON):
Specify whether the TNC
is to issue an error message if the stylus is deflected
at cycle start (0) or not (1). If you select mode 1, the
TNC continues to save the value 2.0 in the 4th result
parameter and continues the cycle.
To conclude the input, press the ENT key.
Example: NC blocks
4 TCH PROBE 3.0 MEASURING
5 TCH PROBE 3.1 Q1
6 TCH PROBE 3.2 X ANGLE: +15
7 TCH PROBE 3.3 DIST +10 F100 MB1
REFERENCE SYSTEM:0
8 TCH PROBE 3.4 ERRORMODE1