beautypg.com

2 pr eset ting aut o matically – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual

Page 100

background image

100

3 Touch Probe Cycles for Automatic Workpiece Inspection

3.2 Pr

eset

ting aut

o

matically

First center in 1st axis

Q268 (absolute): Center of

the 1st hole in the reference axis of the working plane.

First center in 2nd axis

Q269 (absolute): Center of

the 1st hole in the minor axis of the working plane.

Second center in 1st axis

Q270 (absolute): Center of

the 2nd hole in the reference axis of the working
plane.

Second center in 2nd axis

Q271 (absolute): Center of

the 2nd hole in the minor axis of the working plane.

Third center in 1st axis

Q316 (absolute): Center of

the 3rd hole in the reference axis of the working plane.

Third center in 2nd axis

Q317 (absolute): Center of

the 3rd hole in the minor axis of the working plane.

Fourth center in 1st axis

Q318 (absolute): Center of

the 4th hole in the reference axis of the working plane.

Fourth center in 2nd axis

Q319 (absolute): Center

of the 4th hole in the minor axis of the working plane.

Measuring height in the touch probe axis

Q261

(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.

X

Y

Q269

Q268

Q270

Q317

Q271

Q318

Q316

Q319

X

Z

Q261

Q260