3 TCH PROBE 416 DATUM CIRCLE CENTER
Q273=+35
;CENTER 1ST AXIS
Center of the bolt hole circle: X coordinate
Q274=+35
;CENTER 2ND AXIS
Center of the bolt hole circle: Y coordinate
Q262=50
;NOMINAL DIAMETER
Diameter of the bolt hole circle
Q291=+90
;ANGLE OF 1ST HOLE
Polar coordinate angle for 1st hole center
1
Q292=+180
;ANGLE OF 2ND HOLE
Polar coordinate angle for 2nd hole center
2
Q293=+270
;ANGLE OF 3RD HOLE
Polar coordinate angle for 3rd hole center
3
Q261=+15
;MEASURING HEIGHT
Coordinate in the touch probe axis in which the measurement is
made
Q260=+10
;CLEARANCE HEIGHT
Height in the touch probe axis at which the probe can traverse
without collision
Q305=1
;NO. IN TABLE
Enter center of bolt hole circle (X and Y) in line 1
Q331=+0
;DATUM
Q332=+0
;DATUM
Q303=+1
;MEAS. VALUE TRANSFER
In the preset table PRESET.PR, save the calculated datum
referenced to the machine-based coordinate system (REF system)
Q381=0
;PROBE IN TS AXIS
Do not set a datum in the touch probe axis
Q382=+0
;1ST CO. FOR TS AXIS
No function
Q383=+0
;2ND CO. FOR TS AXIS
No function
Q384=+0
;2RD CO. FOR TS AXIS
No function
Q333=+0
;DATUM
No function
4 CYCL DEF 247 DATUM SETTING
Activate new preset with Cycle 247
Q339=1
;DATUM NUMBER
6 CALL PGM 35KLZ
Part program call