53

3.1 Measur

ing W

o

rk

piece Misalignment

First hole: Center in 1st axis

Q268 (absolute):

center of the first hole in the reference axis of the
working plane.

First hole: Center in 2nd axis

Q269 (absolute):

center of the first hole in the minor axis of the working
plane.

Second hole: Center in 1st axis

Q270 (absolute):

center of the second hole in the reference axis of the
working plane.

Second hole: Center in 2nd axis

Q271 (absolute):

center of the second hole in the minor axis of the
working plane.

Measuring height in the touch probe axis

Q261

(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.

Default setting for basic rotation

Q307

(absolute): If the misalignment is to be measured
against a straight line other than the reference axis,
enter the angle of this reference line. The TNC will
then calculate the difference between the value
measured and the angle of the reference line for the
basic rotation.