1 measur ing w o rk piece misalignment – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual
Page 53

HEIDENHAIN iTNC 530
53
3.1 Measur
ing W
o
rk
piece Misalignment
First hole: Center in 1st axis
Q268 (absolute):
center of the first hole in the reference axis of the
working plane.
First hole: Center in 2nd axis
Q269 (absolute):
center of the first hole in the minor axis of the working
plane.
Second hole: Center in 1st axis
Q270 (absolute):
center of the second hole in the reference axis of the
working plane.
Second hole: Center in 2nd axis
Q271 (absolute):
center of the second hole in the minor axis of the
working plane.
Measuring height in the touch probe axis
Q261
(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.
Clearance height
Q260 (absolute): Coordinate in the
touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.
Default setting for basic rotation
Q307
(absolute): If the misalignment is to be measured
against a straight line other than the reference axis,
enter the angle of this reference line. The TNC will
then calculate the difference between the value
measured and the angle of the reference line for the
basic rotation.
X
Y
Q271
Q269
Q268
Q270
X
Z
Q261
Q260