Measuring log
Q281: Definition of whether the TNC is
to create a measuring log:
0: No measuring log
1: Generate measuring log: with the standard setting
the TNC saves the log file TCHPR430.TXT in the
directory in which your measuring program is also
stored.
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.
PGM stop if tolerance error
Q309: Definition of
whether in the event of a violation of tolerance limits
the TNC is to interrupt the program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message
Tool number for monitoring
Q330: Definition of
whether the TNC is to monitor for tool breakage (see
“Tool monitoring” on page 112):
0: Monitoring not active
>0: Tool number in the tool table TOOL.T
Example: NC blocks
5 TCH PROBE 430 MEAS. BOLT HOLE CIRC
Q273=+50
;CENTER 1ST AXIS
Q274=+50
;CENTER 2ND AXIS
Q262=80
;NOMINAL DIAMETER
Q291=+0
;ANGLE OF 1ST HOLE
Q292=+90
;ANGLE OF 2ND HOLE
Q293=+180
;ANGLE OF 3RD HOLE
Q261=-5
;MEASURING HEIGHT
Q260=+10
;CLEARANCE HEIGHT
Q288=80.1
;MAX. LIMIT
Q289=79.9
;MIN. LIMIT
Q279=0.15
;TOLERANCE 1ST CENTER
Q280=0.15
;TOLERANCE 2ND CENTER
Q281=1
;MEASURING LOG
Q309=0
;PGM STOP IF ERROR
Q330=0
;TOOL NUMBER
Note: Only tool breakage monitoring active, no automatic