beautypg.com

3 a u to matic w o rk piece measur ement – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual

Page 139

background image

HEIDENHAIN iTNC 530

139

3.3 A

u

to

matic W

o

rk

piece Measur

ement

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:
0: No measuring log
1: Generate measuring log: with the standard setting
the TNC saves the log file TCHPR430.TXT in the
directory in which your measuring program is also
stored.
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.

PGM stop if tolerance error

Q309: Definition of

whether in the event of a violation of tolerance limits
the TNC is to interrupt the program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message

Tool number for monitoring

Q330: Definition of

whether the TNC is to monitor for tool breakage (see
“Tool monitoring” on page 112):
0: Monitoring not active
>0: Tool number in the tool table TOOL.T

Example: NC blocks

5 TCH PROBE 430 MEAS. BOLT HOLE CIRC

Q273=+50

;CENTER 1ST AXIS

Q274=+50

;CENTER 2ND AXIS

Q262=80

;NOMINAL DIAMETER

Q291=+0

;ANGLE OF 1ST HOLE

Q292=+90

;ANGLE OF 2ND HOLE

Q293=+180

;ANGLE OF 3RD HOLE

Q261=-5

;MEASURING HEIGHT

Q260=+10

;CLEARANCE HEIGHT

Q288=80.1

;MAX. LIMIT

Q289=79.9

;MIN. LIMIT

Q279=0.15

;TOLERANCE 1ST CENTER

Q280=0.15

;TOLERANCE 2ND CENTER

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL NUMBER

Note: Only tool breakage monitoring active, no automatic
tool compensation.