Calibrate ts length (touch probe cycle 9), 4 special cy cles – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual
Page 149

HEIDENHAIN iTNC 530
149
3.4 Special Cy
cles
CALIBRATE TS LENGTH (touch probe cycle 9)
Touch probe cycle 9 automatically calibrates the length of a touch
trigger probe at a point that you determine.
1
Pre-position the touch probe so that the coordinate defined in the
cycle can be accessed without collision.
2
The TNC moves the touch probe in the direction of the negative
tool axis until a trigger signal is released.
3
Finally, the TNC moves the touch probe back to the starting point
of the probing process and writes the effective touch probe length
into the calibration data.
Coordinate of datum
(absolute): Exact coordinate of
the point that is to be probed.
Reference system? (0=ACT/1=REF):
Specify the
coordinate system on which the entered datum is to
be based:
0: Entered datum is based on the active workpiece
coordinate system (ACT system)
1: Entered datum is based on the active machine
coordinate system (REF system)
Example: NC blocks
5 L X-235 Y+356 R0 FMAX
6 TCH PROBE 9.0 CALIBRATE TS LENGTH
7 TCH PROBE 9.1 DATUM +50 REFERENCE
SYSTEM 0