2 pr eset ting aut o matically – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual
Page 95

HEIDENHAIN iTNC 530
95
3.2 Pr
eset
ting aut
o
matically
Center of 1st axis
Q273 (absolute): Bolt hole circle
center (nominal value) in the reference axis of the
working plane.
Center in 2nd axis
Q274 (absolute): Bolt hole circle
center (nominal value) in the minor axis of the working
plane.
Nominal diameter
Q262: Enter the approximate bolt
hole circle diameter. The smaller the hole diameter,
the more exact the nominal diameter must be.
Angle of 1st hole
Q291 (absolute): Polar coordinate
angle of the first hole center in the working plane.
Angle of 2nd hole
Q292 (absolute): Polar coordinate
angle of the second hole center in the working plane.
Angle of 3rd hole
Q293 (absolute): Polar coordinate
angle of the third hole center in the working plane.
Measuring height in the touch probe axis
Q261
(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.
Clearance height
Q260 (absolute): Coordinate in the
touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.
Datum number in table
Q305: Enter the number in the
datum or preset table in which the TNC is to save the
coordinates of the bolt-hole circle center. If you enter
Q305=0, the TNC automatically sets the display so
that the new datum is on the bolt hole center.
New datum for reference axis
Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the bolt-hole center.
Basic setting = 0
New datum for minor axis
Q332 (absolute):
Coordinate in the minor axis at which the TNC should
set the bolt-hole center.
Basic setting = 0
X
Y
Q274
Q273
Q262
Q291
Q293
Q292
X
Y