beautypg.com

2 pr eset ting aut o matically – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual

Page 93

background image

HEIDENHAIN iTNC 530

93

3.2 Pr

eset

ting aut

o

matically

Datum number in table

Q305: Enter the datum

number in the datum or preset table in which the TNC
is to save the coordinates of the corner. If you enter
Q305=0, the TNC automatically sets the display so
that the new datum is on the corner.

New datum for reference axis

Q331 (absolute):

Coordinate in the reference axis at which the TNC
should set the corner. Basic setting = 0

New datum for minor axis

Q332 (absolute):

Coordinate in the minor axis at which the TNC should
set the calculated corner. Basic setting = 0

Measured-value transfer (0, 1)

Q303: Specify

whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use. Is entered by the TNC when old
programs are read in (see “Saving the calculated
datum” on page 69).
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).

Probe in TS axis

Q381: Specify whether the TNC

should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis

Probe TS axis: Coord. 1st axis

Q382 (absolute):

Coordinate of the probe point in the reference axis of
the working plane at which point the reference point
is to be set in the touch probe axis. Only effective if
Q381 = 1.

Probe TS axis: Coord. 2nd axis

Q383 (absolute):

Coordinate of the probe point in the minor axis of the
working plane at which point the reference point is
to be set in the touch probe axis. Only effective if
Q381 = 1.

Probe TS axis: Coord. 3rd axis

Q384 (absolute):

Coordinate of the probe point in the touch probe axis,
at which point the reference point is to be set in the
touch probe axis. Only effective if Q381 = 1.

New datum for touch probe axis

Q333 (absolute):

Coordinate in the touch probe axis at which the TNC
should set the datum. Basic setting = 0

Example: NC blocks

5 TCH PROBE 415 DATUM OUTSIDE CORNER

Q263=+37

;1ST POINT 1ST AXIS

Q264=+7

;1ST POINT 2ND AXIS

Q326=50

;SPACING IN 1ST AXIS

Q296=+95

;3RD POINT 1ST AXIS

Q297=+25

;3RD POINT 2ND AXIS

Q327=45

;SPACING IN 2ND AXIS

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q304=0

;BASIC ROTATION

Q305=7

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;2RD CO. FOR TS AXIS

Q333=+1

;DATUM