beautypg.com

2 pr eset ting aut o matically – HEIDENHAIN iTNC 530 (340 49x-04) Touch Probe Cycles User Manual

Page 101

background image

HEIDENHAIN iTNC 530

101

3.2 Pr

eset

ting aut

o

matically

Datum number in table

Q305: Enter the number in the

datum or preset table in which the TNC is to save the
coordinates of the line intersection. If you enter
Q305=0, the TNC automatically sets the display so
that the new datum is at the intersection of the
connecting lines.

New datum for reference axis

Q331 (absolute):

Coordinate in the reference axis at which the TNC
should set the calculated intersection of the
connecting lines. Basic setting = 0

New datum for minor axis

Q332 (absolute):

Coordinate in the minor axis at which the TNC should
set the calculated intersection of the connecting
lines. Basic setting = 0

Measured-value transfer (0, 1)

Q303: Specify

whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use. Is entered by the TNC when old
programs are read in (see “Saving the calculated
datum” on page 69).
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).

Probe in TS axis

Q381: Specify whether the TNC

should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis

Probe TS axis: Coord. 1st axis

Q382 (absolute):

Coordinate of the probe point in the reference axis of
the working plane at which point the reference point
is to be set in the touch probe axis. Only effective if
Q381 = 1.

Probe TS axis: Coord. 2nd axis

Q383 (absolute):

Coordinate of the probe point in the minor axis of the
working plane at which point the reference point is
to be set in the touch probe axis. Only effective if
Q381 = 1.

Probe TS axis: Coord. 3rd axis

Q384 (absolute):

Coordinate of the probe point in the touch probe axis,
at which point the reference point is to be set in the
touch probe axis. Only effective if Q381 = 1.

New datum for touch probe axis

Q333 (absolute):

Coordinate in the touch probe axis at which the TNC
should set the datum. Basic setting = 0

Example: NC blocks

5 TCH PROBE 418 DATUM FROM 4 HOLES

Q268=+20

;1ST CENTER IN 1ST AXIS

Q269=+25

;1ST CENTER IN 2ND AXIS

Q270=+150

;2ND CENTER IN 1ST AXIS

Q271=+25

;2ND CENTER IN 2ND AXIS

Q316=+150

;3RD CENTER IN 1ST AXIS

Q317=+85

;3RD CENTER IN 2ND AXIS

Q318=+22

;4TH CENTER IN 1ST AXIS

Q319=+80

;4TH CENTER IN 2ND AXIS

Q261=-5

;MEASURING HEIGHT

Q260=+10

;CLEARANCE HEIGHT

Q305=12

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+0

;DATUM